Introduction / Safety
Possible Connections
ISO: 12 V DC
ISO: loudspeaker (max. 2 pairs)
(USB 1.1 and 2.0) SD or MMC
Max. four amplifiers
Display
Liquid crystal screen
3 Band PLL Tuner
Display: frequency band, radio stations, mono or stereo reception,
FM-Band (FM 1, FM 2, FM 3)
Frequency band:
Channel increments: 50 kHz
Intermediate frequency: 10.7 MHz
Stereo separation: 30 dB
Noise suppression: 55 dB
Preset stations: 18
MW Band (MW)
Frequency band:
Interim frequency: 450 kHz
Available sensitivity: 32 dB µV
LW Band (LW)
Frequency band:
Interim frequency: 450 KHz
Available sensitivity: 32 dB µV
IR Remote Control Rated voltage: 3 V DC
Power supply: 1 x lithium battery type CR2025, 3 V DC
Current consumption: approx. 30 mA
Wavelength range: near infrared
Dimensions: 85 x 6 x 52 mm (L x H x B)
GB/IE
KH2391_Content_UK.indd 8
LAudio Storage Media
Playback
Data formats: MP3 with ID3, WAV compatible
Media: CD,
2.0(stick or
Display: directory, file, track, album, artist, duration
Search function: file, track, first letter are displayed
LSafety
Important Safety Instructions
The following instructions are provided for your safety and satisfaction when operating the device. Please note that
Explanation of the symbols and terms used:
cWarning! Danger of death!
mCaution! Risk of injury and damage to materials! Tip! What course of action you should follow!
cWarning!
·Do not leave small children unsupervised near the packaging material! Otherwise there is a danger of death through suffocation!
·Do not leave small children unsupervised in the vicinity of the device!
·Protect yourself against electric shock! Avoid any short circuits during connection:
-to the 12 V DC power supply of the vehicle
-to the max. 2 pairs of loudspeakers with an impedance of
-to an amplifier
·Before connecting to the 12 V DC supply of a car, obtain information on how to maintain electrical safety from the vehicles operation manual!
·When connecting to the 12 V DC power supply of a vehicle, ensure that there is no voltage in the vehicle’s connection cables. Equip the con- nection cables with fuse holders (2 x 15 A)!
05.09.2006 14:49:10 Uhr