GE Monogram ZX2L SS installation instructions Provide Gas Supply, LP GAS Models

Page 7

Installation

Dual Burner Outdoor Cooktop

Step3

Provide

Gas

Supply

LP GAS MODELS

Go to Step 3A

For Natural

Gas Model

Connections

WARNING PRODUCT STORAGE When storing the LP burner indoors, disconnect the LP tank. Store the tank outdoors in a well ventilated area.

Do not store spare LP tanks near or below the burner installation.

For installation with a 27" LP gas grill that does not feature the new Quick Disconnect coupling.

Completely close the main valve on the LP tank supplying the grill.

Apply joint compound to the threaded end of the cooktop gas inlet.

Tighten the 1/2" NPT x 3/8" flare fitting to the cooktop gas outlet. Do not use threading compound on the male threads.

Attach hose to end of fitting and tighten.

Route the hose through the hole with protective bushing on the side of the grill cart.

Attach the hose ends from the grill and the cooktop to the ends of the supplied 3/8" flare tee as shown.

Attach the original LP Regulator hose assembly to the 3/8" flare tee as shown.

Go to “Test for Leaks” Step 4.

To Manifold

of Grill1/2" NPT x

3/8" Flare Fitting

To Cooktop

3/8" Flare Tee

From

Regulated

L.P. Tank

LP Connection with ZX27QDC Kit For Quick Disconnect Coupling System

For Installation with a 27" LP Gas Grill featuring Quick Disconnect couplings.

Completely close the main valve on the LP tank supplying the grill.

Apply joint compound to the threaded end of the cooktop gas inlet.

Tighten the 1/2" NPT x 3/8" flare fitting to the cooktop gas outlet. Do not use threading compound on the male threads.

Attach hose to end of fitting and tighten.

NOTE: To connect the Quick Disconnect couplings, pull back and hold the outer sleeve of the female coupling while inserting the male hose end. Release the outer sleeve to lock. To test the connection, firmly grasp each part and attempt to pull apart. Once locked, they should not separate.

1/2" NPT x

 

3/8" Flare

 

Fitting

24" Quick

 

 

Disconnect Hose

To Manifold

 

of Grill

Quick

 

Disconnect

To L.P.

Tee

Regulator

 

 

• Attach the hose from the grill to the opposite

• Route the cooktop LP hose through the

female end of the quick disconnect tee.

panel bushing on the right side of the cart.

• Secure the bottom male end of the quick

• Insert the male hose end from the cooktop

disconnect tee to the female quick disconnect

burner into one end of the quick disconnect

LP tank regulator assembly.

tee.

• Go to “Test for Leaks” Step 4.

7

Image 7
Contents Liquid Propane Contents Advance Planning Product Dimensions ClearancesAccessories Models AvailableRemove the Packaging For Natural Gas InstallationsTools Materials Required Choosing the LocationSecure Cooktop to Support Brackets Installation On 27 CartSecure Support Brackets to Grill Secure Cooktop to Grill HeadInstallation Into An Enclosure LP GAS Models Provide Gas SupplyNatural GAS Models Provide Gas SupplyLighting the Burner Test for LeaksLow setting Adjustment Finalize InstallationAdjusting the Burners To AdjustDual Burner Outdoor Cooktop Monogram