GE Monogram ZX2L SS installation instructions Test for Leaks, Lighting the Burner

Page 9

Installation

Dual Burner Outdoor Cooktop

Step4

Test for Leaks

WARNING TEST FOR LEAKS A complete gas tightness check must be performed at the installation site. DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.

Do not use the burner until all connections have been leak tested.

Repeat leak test after each LP tank change or gas re-connect.

Check to be sure the main valve on the LP tank or the shut-off valve is in the “OFF” position.

Make a soap solution of one part liquid detergent and one part water.

The valve panel must be removed to check the valves and fittings.

All control valves should be in the “OFF” position.

Remove the knobs.

Remove the 4 screws holding the valve panel to the burner.

Pull the panel outwards and unplug the wire from the back of the rotary igniter.

TO TEST:

Apply the soap solution around all connections, valve and tubing.

Turn the gas supply on.

Check all connections from the supply line or LP tank up to and including the manifold pipe assembly.

If a leak is detected, turn gas supply off and tighten fittings. Turn the gas on and check again.

To re-install the valve panel, re-connect the igniter wire and secure the panel with original screws.

Step5

Lighting the Burner

WARNING Do not attempt to light the burner if the odor of gas is present.

CAUTION: Keep hands and face as far away from the burner as possible when lighting.

Remove burner cover.

Turn all knobs to “OFF” position.

Turn gas supply on at the LP tank or shut-off

valve.

NOTE: When lighting the burner for the first time or after a LP tank change, up to 20 seconds may be required to purge air from the lines.

Push and turn control knob counter-clockwiseto “LITE” position, turn the small igniter knob next to the burner knob clockwise.

NOTE: The spark will produce a snapping sound. This is normal.

If the burner does not light within 4 seconds, turn knobs to “OFF and wait 5 minutes for the gas to dissipate before trying again.

If the burner does not light after several attempts, the burner can be lit with a match.

TO MATCH LIGHT:

Remove the burner grate.

Strike match and hold adjacent to burner port.

Push and turn the control knob to “LITE”.

Rotate the control knob to desired setting.

Replace grate.

ALWAYS TURN GAS SUPPLY OFF AT THE SHUT-OFF VALVE OR LP TANK WHEN NOT IN USE.

9

Image 9
Contents Liquid Propane Contents Accessories Product Dimensions ClearancesModels Available Advance PlanningTools Materials Required For Natural Gas InstallationsChoosing the Location Remove the PackagingSecure Support Brackets to Grill Installation On 27 CartSecure Cooktop to Grill Head Secure Cooktop to Support BracketsInstallation Into An Enclosure LP GAS Models Provide Gas SupplyNatural GAS Models Provide Gas SupplyLighting the Burner Test for LeaksAdjusting the Burners Finalize InstallationTo Adjust Low setting AdjustmentDual Burner Outdoor Cooktop Monogram