E-F Balance (1 Track Jump) Check (Without remote commander)
oscilloscope
BD (CD) board |
|
TP (TEO) | + |
TP (VC) | – |
Procedure :
1.Connect oscilloscpe to test point TP (TEO) on BD board.
2.Turn Power switch on.
3.Put disc
4.Press the “ P(Pause)” button. (Becomes the 1 track jump mode)
5.Confirm that the oscilloscope waveform is symmetrical on the top and bottom in relation to 0Vdc, and check this level.
1 track jump waveform
A
0V
B
LEVEL : 300 ± 100
A – B
Specified level: • 2 (A + B) x 100 = less than ± 7%
• A + B = 300 ± 100
Focus/Tracking Gain Adjustment (RV102, RV103)
This gain has a margin, so even if it is slightly off. There is no problem.
Therfore, do not perform this adjustment.
Please note that it should be fixed to mechanical center position when you moved and do not know original position.
Adjustment Location:
[BD (CD) BOARD] — Component Side —
RF
|
| FOK |
| (Focus Bias Adjust) |
|
RV101 |
| IC102 |
| TEI | |
| IC101 |
|
RV103 |
|
|
TEO | FEO |
|
FEI |
| |
VC | RV102 |
|
|
|
IC104
PCK
GND