SECTION 5
TEST MODE
AGING MODE
This unit is equipped with an aging mode.
Use this mode for analyzing defects and for checks after completing repairs. After repairs, perform aging 100 times and check that the unit is normal. The aging mode is executed in the following sequence.
The aging mode will continue as long as the unit is normal.
If the unit becomes abnormal, it will display the state and number of cycles, and operations will stop. (Refer to Table 1.)
Sequence of Aging Mode:
Start
Sets the CD function and reads the CD TOC.
CD TOC OK? | NO |
Message 1 |
YES
Pauses first song.
OK?
YES
NO
Message 2
Last song search paused state
OK? |
| NO | Message 3 | ||||
|
|
|
| ||||
|
|
|
|
|
| ||
YES |
|
|
|
|
|
|
|
|
|
|
|
| |||
Starts last song playback |
|
|
|
| |||
|
|
|
|
|
|
|
|
OK? | NO |
Message 4 | |
YES |
|
End playback? | NO |
| |
YES | OK |
| Is CD playing? |
| NG |
Opens the CD tray | Message 4 |
OK? | NO |
Message 5 | |
YES |
|
Closes the CD tray |
|
OK? | NO | |||
| Message 6 | |||
| ||||
YES |
|
|
|
|
|
|
| ||
Power OFF |
|
|
Display of number of aging cycles
Power ON
Procedure:
1.Press the DISPLAY button and =/TUNING/0
2.To end aging, press the u button and end.
button together.
No | Error Messages | Details of Error | Main Causes |
1 | CD No Disc NG | Cannot read CD TOC. | Optical defect, spindle defect (including motor), cannot read |
|
|
| Q data, disc defect (scratches, etc.), bad focus, bad GFS, etc. |
2 | CD Pause NG | Cannot set CD pause in | Disc defect (scratches, etc.), cannot read Q data, etc. |
|
| CD synchro mode. |
|
3 | CD Search NG | Cannot search last track on CD. | Optical defect, sled, tracking defect (including motor), cannot |
|
|
| read Q data, disc defect (scratches, etc.). |
4 | CD Play NG | Cannot play last track on CD. | Optical defect, cannot read Q data, disc defect (scratches, etc.), |
|
|
| etc. |
5 | CD Open NG | Cannot open CD tray. | LOAD OUT SW defect |
6 | CD Close NG | Cannot close CD tray. | LOAD IN SW defect |
|
|
|
|
– 13 –