NOTE 2

FOR MULTI SYSTEM AIR CONDITIONER

OUTDOOR UNIT : MXZ series

Multi system air conditioner can connect two or more indoor units with one outdoor unit.

•When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and the others for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor units cannot operate, indicating as shown in the figure below. In this case, please set all the indoor units to the same operation mode.

L AREA R

POWER CLEAN PLASMA

Lighted

 

 

Blinking

 

 

Not lighted

•When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes(max. 10 minutes) to blow out the warm air.

•In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant flow- ing may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.

9-5. AUTO VANE OPERATION

1.Horizontal vane

(1)Vane motor drive

These models are equipped with a stepping motor for the horizontal vane. The rotating direction, speed, and angle of the motor are controlled by pulse signals (approx. 12 V) transmitted from indoor microprocessor.

(2)The horizontal vane angle and mode change as follows by pressing VANE CONTROL button.

(3)Positioning

To confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selected angle.

Confirming of standard position is performed in the following cases:

(a)The operation starts or finishes (including timer operation).

(b)The test run operation starts.

(c)Standby mode (only during multi system operation) starts or finishes.

(4)VANE AUTO ( ) mode

The microprocessor automatically determines the vane angle to make the optimum room temperature distribution.

COOL and DRY operation

HEAT operation

Vane angle is fixed to Angle 1.

Vane angle is fixed to Angle 4.

1

(5)STOP (operation OFF) and ON TIMER standby

In the following cases, the horizontal vane returns to the closed position.

(a)When OPERATE/STOP (ON/OFF) button is pressed (POWER OFF).

(b)When the operation is stopped by the emergency operation.

(c)When ON TIMER is ON standby.

(6)Dew prevention

During COOL or DRY operation with the vane angle at Angle 3 ~ 5 when the compressor cumulative operation time exceeds 1 hour or 30 minutes, the vane angle automatically changes to Angle 2 for dew prevention.

13

Page 13
Image 13
Mitsubishi Electronics MSZ-FD25VAS, MSZ-FD35VAS service manual Auto Vane Operation, Outdoor Unit MXZ series, Horizontal vane