All lamps flash ON and OFF every
E Check of installation of the horizontal vane
Turn OFF the power supply.
Is the stopper of the horizontal vane | No |
| |
locked to the indoor unit correctly? |
|
Yes |
|
To check the continuity of the interlock switch (Fan), measure the resistance of connector 1 - 2 connected to CN1R1 on the indoor electronic control P.C. board.
Relock the stopper of the horizontal vane to the indoor unit. (Refer to
Turn ON the power supply.
No
Are all lamps flashing? | OK |
Yes
Turn OFF the power supply.
No(∞ )
Is there resistance 0 "?
Yes
Replace the indoor electronic control P.C. board.
Replace the interlock switch(Fan).
PLASMA lamp flashes
POWER lamp flashes 1 to 5 times while PLASMA operation failure mode (Refer to
F Check of PLASMA operation
After performing the check, make sure to release the failure mode recall function.
Turn ON the power supply.
Does PLASMA lamp flash | Yes |
| |
|
No
1While pressing both OPERATION SELECT button and
TOO COOL button on the remote controller at the same time, press RESET button.
2First, release RESET button.
And release the other two buttons after all LCD except the set temperature in operation display section of the remote controller is displayed after 3 seconds.
3Press OPERATE/STOP (ON/OFF) button (the set temperature is displayed)
4And press PLASMA button once with the remote controller
headed towards the indoor unit. w1 PLASMA operation is selected.
wThe plasma operation check mode is set.(Refer to
High voltage (approx.
Pay careful attention and never touch PLASMA ELECTRODE UNIT and the
Replace the indoor electronic control P.C. board.
PLASMA operation
w1 Regardless of normal or abnormal condition, a short beep is emitted once the signal
is received.
Does PLASMA lamp stay OFF, or continuously | OFF | |
Normal | ||
blink? | ||
|
| w2 Turn PLASMA operation OFF and ON again. |
Continuously blinking. | (For turning OFF PLASMA operation, refer to |
| (If it goes normal without turning OFF and ON, PLASMA lamp doesn't go OFF.) |
Replace the PLASMA POWER P.C. board.
32