Indoor unit installation location and air-conditioning area

Installed at left

Installed at center

Installed at right

 

LEFT

RIGHT

LEFT

RIGHT

LEFT

RIGHT

·Be sure to set the slide switch inside the remote controller to an appropriate position in accordance with the installed position of the indoor unit. If the switch is not set correctly, the air conditioner may not function properly.

(Refer to "Remote controller in SERVICE FUNCTIONS".)

 

To air-condition mainly

To air-condition the entire room

To air-condition mainly

 

the left area of the room

The horizontal air flow direction and in-

the right area of the room

 

 

 

 

door unit display are switched accord-

 

 

 

 

 

 

 

ing to the room temperature (floor/wall).

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote controller button

Press AREA button

Press AREA button to select AUTO.

Press AREA button

to select LEFT.

to select RIGHT.

 

 

 

 

Remote controller display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i-see Sensor operation

Control range

Installed

 

 

 

 

 

 

 

 

 

 

 

 

of horizontal air at center

 

 

 

 

 

 

 

 

 

 

 

 

flow direction.

 

 

 

 

 

 

 

 

 

 

 

 

 

The vertical air

 

 

 

 

 

 

 

 

 

 

 

 

 

flow direction

Installed

 

 

 

 

 

 

 

 

 

 

 

 

conforms to the at left

 

 

 

 

 

 

 

 

 

 

 

 

setting on the

 

 

 

 

 

 

 

 

 

 

 

 

 

remote controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

(The horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

air flow direction Installed

 

 

 

 

 

 

 

 

 

 

 

 

is controlled in

at right

 

 

 

 

 

 

 

 

 

 

 

 

this range.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

AREA

L

R

L

R

or

L

R

or

L

R

L

R

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lighted Not lighted

When AREA is set to AUTO

•The vertical vane is controlled to maintain uniform temperature in the whole room.

•The i-see Sensor moves in a range of 150 degrees detecting floor/wall temperature of 3 areas (left, right, center). Therefore, the detected temperatures may be different from the temperatures measured on commercial thermometers depending on the condition or temperature distribution on the floor and/or wall.

Ex.) In COOL mode

Approx. 150 degrees

Moving of horizontal air flow direction

Daytime

Warm area

Nighttime

Cold area

display

Indoor unit NOTE

The indoor unit delivers cold air detecting the warm area in the room.

Indication of AREA setting

 

L AREA R

L AREA R

·The horizontal air flow direction changes if i-see Sensor detects approx. 3 : temperature difference.

·In AUTO of AREA setting, both right and left lamps are lighted when the room is evenly air-conditioned.

L AREA R

Lighted

Not lighted

16

Page 16
Image 16
Mitsubishi Electronics MSZ-FD25VAS, MSZ-FD35VAS service manual Daytime