Mitsubishi Electronics MSZ-FD35VAS, MSZ-FD25VAS service manual Plasma

Models: MSZ-FD25VA MSZ-FD35VA MSZ-FD35VAS MSZ-FD25VAS

1 40
Download 40 pages 13.16 Kb
Page 26
Image 26

 

L AREA R

POWER CLEAN

PLASMA

 

 

No.

Abnormal

 

Operation indicator lamp

Symptom

Condition

Correspondence

 

point

 

 

 

 

 

 

Attachment

All lamps flash at the same time.

Indoor unit

 

 

 

0.5-second ON

The electricity is not conducted to the interlock

• Refer to 10-6.E"Check of

 

of the

and outdoor

1

installation of the horizontal

 

horizontal

 

 

unit do not

switch (Fan) of the horizontal vane.

vane".

 

vane

 

 

operate.

 

 

 

 

 

 

0.5-second OFF

L AREA R POWER CLEAN PLASMA

No.

Abnormal

Operation indicator lamp

 

point

 

POWER lamp is lighted.

MXZ type AREA lamps flash. Operation

1 mode setting

2.5-second OFF

Symptom

Outdoor unit operates but indoor unit does not operate.

Condition

Correspondence

The operation mode of the each indoor unit is

• Unify the operation mode.

differently set to COOL (includes DRY) and

Refer to outdoor unit service

HEAT at the same time, the operation mode of

manual.

the indoor unit that has operated at first has the

 

priority.

 

 

L AREA R

POWER CLEAN

PLASMA

 

No.

Abnormal

 

Operation indicator lamp

Symptom

Condition

 

point

 

 

 

 

 

 

PLASMA lamp flashes.

Indoor unit

PLASMA operation can not be turned OFF

 

 

2-time flash

 

PLASMA

and outdoor

1

even if the PLASMA operation is turned OFF

 

 

control

 

 

unit do not

 

 

with remote controller.

 

 

 

 

operate.

 

 

2.5-second OFF

 

 

 

 

 

Correspondence

Refer to 10-6.F"Check of PLASMA operation".

26

Page 26
Image 26
Mitsubishi Electronics MSZ-FD35VAS, MSZ-FD25VAS service manual Plasma