Indoor unit operates by pressing EMERGENCY OPERATION switch, but does not operate with the remote controller.
B Check of remote controller and indoor electronic control P.C. board
wCheck if the remote controller is exclusive for this air conditioner.
Press OPERATE/STOP(ON/OFF) button on the remote controller.
Is LCD display on the remote con- | No |
| |
troller visible? |
|
(not clear)
Yes
Replace the batteries. (Refer to
Remove the batteries, then set them back and press RESET button. (Refer to 10- 1.4.) Check if the unit operates with the remote controller.
Does the unit operate with the | No |
| |
remote controller? |
|
Yes |
|
Turn ON a radio to AM and press OPERATE/STOP(ON/OFF) button on the remote controller.
OK |
Is noise heard from radio? |
|
| No | ||
|
|
|
| ||
| Yes |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| |
Are there any fluorescent lights of |
|
| Yes | ||
inverter or |
|
|
|
| |
|
|
|
| ||
the range of 1 m? |
|
|
|
| |
| No |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
Replace the indoor electronic |
|
|
|
| |
control P.C. board. |
|
|
|
| |
(including the receiver) |
|
|
|
| |
|
|
|
|
|
|
Replace the remote controller.
●Reinstall the unit away from lights.
●Attach a filter on receiving part.