Sony MZ-E707 000 P**P##, 000 P**R00 000 EIB Stat Adrs BEmp 000 ######, 000 FF, Rplay, Set Ok

Page 11

MZ-E707

4-7. SOUND SKIP CHECK RESULT DISPLAY MODE

This set can display and check the error count occurring during play.

Setting method of Sound Skip Check Result Display Mode

1. Setting the test mode.

2. Press the > N key activates the sound skip check result display mode where the LCD displays as shown below.

LCD display

000P**P##

Total of play system error count

Total of record system error count

3.When > N key is pressed, the total of error count is dis- played on the LCD, and each time the > N key is pressed, the error count descents one by one as shown below. Also, when

. key is pressed, the error count ascends by one.

000P**R00

000 EIB **

000Stat**

000Adrs**

000BEmp**

000######

P**R00 : Total of play system error and record system error count

** : Sound skip check items counter (hexadecimal)

#####: 6-digit address (hexadecimal) where a sound skipped Error code

 

Cause of error

Description of error

 

 

 

Playback

EIB

Sound error correction error

 

 

 

 

Stat

Decorder status error

 

 

 

 

Adrs

Cannot access the address

 

 

 

 

BEmp

Buffer becomes empty

4.Quit the sound skip check result display mode, and press the x key to return to the test mode. (display check mode)

4-8. KEY CHECK MODE

4-8-1. Outline of the function

This mode is used to check to make sure that each of the keys (including the slide switch) on the set operates normally.

4-8-2. Setting the Key Check mode

1.Set the TEST MODE. Press and hold down DISPLAY key (for more than 3 sec) to set the Key Check mode.

LCD display

000

2.When each key on the set and on remote control is pressed, its name is displayed on the LCD. (The operated position is dis- played for 4 sec after the slide switch is operated. If any other key is pressed during this display, the LCD switches to its name display)

Example: When > N key on the set is pressed: LCD display

000FF

Example: When > N key on the remote control is pressed:

LCD display

000rPLAY

XX:AD value of the remote control key (hexadecimal 00 to FF)

3.When all the keys on the set and on the remote control are con- sidered as OK, the following displays are shown for 2 sec. (The key pressed to enter the Key Check mode has been checked even if it is not pressed in this mode)

Example: When the keys on the set are considered as OK: LCD display

888SET OK OF

Example: When the keys on the remote control are considered as OK:

LCD display

888RMC OK OX

4.When all the key have been checked or when the top panel is opened during this checking, the system terminates the Key Check mode and return to the TEST MODE.

11

Image 11
Contents 873-338-02 SpecificationsGeneral Table of ContentsDisassembly DiagramsSection Servicing Note General SectionMechanism Assy DisassemblyUpper LID Assy Main Board SUB ASSY, SW Board Bracket R AssyOptical PICK-UP Assy Test Mode Structure Section Test ModeSetting the Test Mode 011 063B01 Manual011 C68S01 OFFJ01001 1 Adrs Clearing the error display code000 FF 000 P**P##000 P**R00 000 EIB Stat Adrs BEmp 000 ###### 000Res OK? ResetVclPWM Res NV CCOfstOK VlPWMAssy11 OfstRes Clr MO OKResume CC 043 ResMZ-E707 Explanation of IC Terminals DiagramsMain Board Block DiagramsSemiconductor Location Printed Wiring Boards Main /2Refer to page 24 for Notes Main Board Side B Main Board RMC KEY Group Printed Wiring Boards Audio SectionLED R LED G LED O SET KEY IC Block Diagrams IC501 SN761057DBT IC551 SC111258FCR2 Main Section Section Exploded Views6460 Mechanism Deck Section MT-MZE707-173Resistors Audio Main Electrical Parts ListDiode Network Resistor Main SWRevision History