4-4. MANUAL MODE
4-4-1. Outline of the function
The Manual mode is designed to perform adjustments and operational checks on the set’s operation according to each individual function.
Usually, no adjustments are made in this mode.
However, the Manual mode is used to clear the memory before performing automatic adjustments in the Overall Adjustment mode.
1.Set the TEST MODE and press + key to set the Manual mode. Remote control LCD display
000Manual
2.During each test, press and hold down > N key or . key for a while to move the optical pickup on the sled outer or inner perimeter.
3.Each test item is assigned with a
MZ-E707
4.During each test mode, the display is changed from one to another each time DISPLAY key is pressed.
•Address & Adjusted Value Display LCD display
011C68S01
address | adjusted value |
mode number
•Jitter Value & Adjusted Value Display LCD display
011OFFJ01
jitter value | adjusted value |
mode number
•Block Error Value & Adjusted Value Display LCD display
011063B01
|
|
|
|
| adjusted value |
block error value |
mode number
Change Major
Item
|
|
|
|
|
|
|
| key |
| x key | |
|
|
| |||
> N |
| ||||
|
|
|
|
| |
|
|
|
|
|
|
|
| Change Middle |
| ||
|
| Item |
|
|
|
|
| key |
| x key | |
|
|
| |||
> N | |||||
|
|
|
|
| |
|
|
|
|
|
|
|
| Change Minor |
| ||
|
| Item |
|
|
|
+key : 100th place of mode number increase
key : 100th place of mode number decrease
+key : 10th place of mode number increase
key : 10th place of mode number decrease
>N key : Unit place of mode number increase
.key : Unit place of mode number decrease
•ADIP Error Value & Adjusted Value Display LCD display
011059A01
|
|
|
|
| adjusted value |
ADIP error value |
mode number
•Item Title Display LCD display
011 LrefPw 01
item |
| title | adjusted value |
|
mode number
Change Adjustment | + key : Up |
Value | key : Down |
Write Adjustment
Value
Xkey : When adjusted value is changed : Adjusted value is written.
When adjusted value is not changed : That item is adjusted automatically.
Note: In the Power mode, the item title display is only displayed.
5.To terminate the Manual mode and return to the TEST MODE, press x key.
4-5. OVERALL ADJUSTMENT MODE
This mode is designed to adjust the servo system automatically by going through all the adjustment items.
Usually, this mode is used to perform automatic adjustments when servicing the set.
For further information, refer to section 5. ELECTRICALADJUST- MENTS. (See page 12)
4-6. SELF-DIAGNOSTIC DISPLAY MODE
The
This history, which can be viewed in the TEST MODE, provides the means of locating the fault in troubleshooting.
9