SECTION 5

ELECTRICAL ADJUSTMENTS

5-1. GENERAL

In this set, CD and MO discs can be automatically adjusted by set- ting the Overall Adjustment mode within the TEST MODE, Before performing these automatic adjustments, it is necessary to clear the memory and adjust the power in the Manual mode.

5-2. NOTES FOR ADJUSTMENT

5-2-1. Jigs

 

CD disc

TDYS-1 (part code: 4-963-646-01)

MO disc

PTDM-1 (part code: J-2501-054-A)

 

 

or commercially available MO disc (recorded)

Digital voltmeter

5-2-2. Adjustment sequence

The adjustments should be always performed in the following sequence:

5-4. MANUAL POWER ADJUSTMENTS

5-4-1. Adjustment sequence

The adjustments should be always performed in the following se- quence:

1Vc PWM Duty (L) adjustment (item No.:762)

r

2 Vl PWM Duty adjustment (item No.:764) r

3 Vd PWM Duty adjustment (item No.:765)

5-4-2. Vc PWM Duty (L) adjustment method

1.

Confirm that the power voltage is at 1.5 V DC.

2.

Set the TEST MODE.

3. Set the overall adjustment mode and press PLAY MODE key,

1Reset NV (Clear the memory)

2Manual power adjustments

3Electrical offset adjustments (Do not enter the disc)

4Overall CD adjustments

5Overall MO adjustments

6RESUME clear

7Rewrite the NV value

5-2-3. Power

Manual mode

Overall adjustment mode

item No. will change to 762.

LCD display

762 VclPWM XX

4.Connect a digital voltmeter to TP901 (VC) on the main board and adjust + key (voltage up) and – key (voltage down) on the remote control.

Adjustment value:2.35V

Standard value:2.34 to 2.355V

MAIN BOARD (SIDE A)

L901

TP901

The power is supplied with 1.5 V DC from the battery case.

5-3. RESET NV

5-3-1. How to reset NV

1.Set the TEST MODE.

2.Set the Manual mode and set the item No. 021, Reset NV. LCD display

021 Res NV CC

3.Press X key on the remote control. LCD display

021 Res OK?

4.Press X key on the remote control again. LCD display

021 Res ***

After reset is completed.

021Reset!

5.Press x key to terminate the Manual mode and return to the

TEST MODE.

 

 

 

 

L905

 

(VC)

R909

 

 

 

 

C907

C921

C909

C910

R910

 

C908

 

R903

28

25

 

20

15

D903

 

29

 

 

 

14

 

C905

30

IC901

 

R964

 

 

10

 

 

 

 

 

 

 

 

digital voltmeter

 

 

 

 

 

 

 

TP901 (VC)

 

5. Press X key to write the adjustment value.

12

Image 12
Contents Specifications 873-338-02Table of Contents DisassemblyDiagrams GeneralSection Servicing Note Section GeneralDisassembly Upper LID AssyMechanism Assy Bracket R Assy Main Board SUB ASSY, SW BoardOptical PICK-UP Assy Section Test Mode Setting the Test ModeTest Mode Structure Manual 011 C68S01OFFJ01 011 063B01Clearing the error display code 001 1 Adrs000 P**P## 000 P**R00 000 EIB Stat Adrs BEmp 000 ######000 000 FFReset VclPWMRes NV CC Res OK?VlPWM Assy11Ofst OfstOKMO OK Resume CC043 Res Res ClrMZ-E707 Diagrams Explanation of IC TerminalsBlock Diagrams Main BoardPrinted Wiring Boards Main /2 Refer to page 24 for NotesSemiconductor Location Main Board Side B Main Board RMC KEY Printed Wiring Boards Audio Section GroupLED R LED G LED O SET KEY IC Block Diagrams IC501 SN761057DBT IC551 SC111258FCR2 Section Exploded Views Main SectionMechanism Deck Section MT-MZE707-173 6460Audio Main Electrical Parts List ResistorsDiode Main SW Network ResistorRevision History