MZ-N505
49)Select manual mode of the test mode, and set item number 871 (see page 14).
Set LCD display
871###S**
###: Address
**: Adjusted value
50)Adjust with the [VOL +] key (adjusted value up) or [VOL
51)Press the X key to write the adjusted value.
52)Select manual mode of the test mode, and set item number 872 (see page 14).
Set LCD display
872###S**
###: Address
**: Adjusted value
53)Adjust with the [VOL +] key (adjusted value up) or [VOL
54)Press the X key to write the adjusted value.
55)Select manual mode of the test mode, and set item number 873 (see page 14).
Set LCD display
873###S**
###: Address
**: Adjusted value
56)Adjust with the [VOL +] key (adjusted value up) or [VOL
57)Press the X key to write the adjusted value.
58)Select manual mode of the test mode, and set item number 874 (see page 14).
Set LCD display
874###S**
###: Address
**: Adjusted value
59)Adjust with the [VOL +] key (adjusted value up) or [VOL
60)Press the X key to write the adjusted value.
POWER SUPPLY MANUAL ADJUSTMENT
• Adjustment Sequence
Adjustment must be done with the following steps.
1.Vc PWM Duty (L) adjustment (item number: 762) r
2.Vc PWM Duty (H) adjustment (item number: 763) r
3.Vl PWM Duty (L) adjustment (item number: 764) r
4.Vl PWM Duty (H) adjustment (item number: 765) r
5.Vrec PWM Duty (L) adjustment (item number: 766) r
6.Vrec PWM Duty (H) adjustment (item number: 767)
• Setting Method of Power Supply Manual Adjustment
1.Make sure that the power supply voltage is 3V.
2.Select the manual mode of the test mode (see page 14).
3.Set item number.
•Adjustment Method of Vc PWM Duty (L) (item number: 762)
Set LCD display
762AD **
**: Adjusted value
1.Connect a digital voltmeter to the AP912 (VCO) on the MAIN
board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
AP912 (VCO)
AP602 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (See page 25)
•Adjustment Method of Vc PWM Duty (H) (item number: 763)
Set LCD display
763AD **
**: Adjusted value
1.Connect a digital voltmeter to the AP912 (VCO) on the MAIN
board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
AP912 (VCO)
AP602 (GND)
22