2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (See page 25)
•Adjustment Method of Vl PWM Duty (L) (item number: 764)
Set LCD display
764AD **
**: Adjusted value
1.Connect a digital voltmeter to the AP913 (VLO) on the MAIN
board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
AP913 (VLO)
AP602 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (See page 25)
•Adjustment Method of Vl PWM Duty (H) (item number: 765)
Set LCD display
765AD **
**: Adjusted value
1.Connect a digital voltmeter to the AP913 (VLO) on the MAIN
board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
AP913 (VLO)
AP602 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (See page 25)
•Adjustment Method of Vrec PWM Duty (L) (item number: 766)
Set LCD display
766AD **
**: Adjusted value
MZ-N505
1.Connect a digital voltmeter to the TP (VREC) on the MAIN
board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
TP (VREC)
AP602 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (See page 25)
•Adjustment Method of Vrec PWM Duty (H) (item number: 767)
Set LCD display
767AD **
**: Adjusted value
1.Connect a digital voltmeter to the TP (VREC) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
TP (VREC)
AP602 (GND)
2. Press the X key to write the adjusted value.
Adjustment and Connection Location: MAIN board (See page 25)
TEMPERATURE COREECTION
• Adjustment Method of Temperature Correction
1.Select the manual mode of test mode, and set the item number 015 (see page 14).
Set LCD display
015###S**
###: Address
**: Adjusted value
2.Measure the ambient temperature.
3.Adjust with [VOL +], [VOL
(hexadecimal value) becomes the ambient temperature. (Initial value: 19h = 25 ° C, Adjusting range: 80h to 7fh
4.Press the X key to write the adjusted value.
23