MZ-N505
•Change of NV Adjusted Values (version 1.100)
Caution: Change the NV adjustment values according to the mi- crocomputer version.
In this set, some adjusted values were set in the manual mode at the shipment, but these will be cleared when the NV is reset. Therefore, modify the NV adjusted values through the following procedure immediately after the NV was reset.
1.Item numbers in which the NV adjusted values are to be modi- fied
–Change ABCD gain [Hpit] initial value (item number 336) Caution: The ABCD gain [Hpit] initial value must be changed before the overall adjustment.
–Change BatFlg value (item number 741)
–Change NiRec0 to 4 values (item numbers 771 to 775)
–Change NiPb 1 to 4 values (item numbers 776 to 779, 781)
–Change CLV drive voltage limiter (item numbers 865, 866)
–Change x2 CLV speed gain, +6dB compared to conventional (item numbers 867, 868)
–Change x2 CLV phase gain, +3dB compared to conventional (item numbers 871, 872)
–Change x2/x1 switching temperature threshold value (+10° C t +5° C) (item numbers 873, 874)
2.NV adjusted values modifying procedure
1)Select manual mode of the test mode, and set item number 336 (see page 14).
Set LCD display
336###S**
###: Address
**: Adjusted value
2)Adjust with the [VOL +] key (adjusted value up) or [VOL
3)Press the X key to write the adjusted value.
4)Select manual mode of the test mode, and set item number 741 (see page 14).
Set LCD display
741AD **
**: Adjusted value
5)Adjust with the [VOL +] key (adjusted value up) or [VOL
6)Press the X key to write the adjusted value.
7)Select manual mode of the test mode, and set item number 771 (see page 14).
Set LCD display
771AD **
**: Adjusted value
8)Adjust with the [VOL +] key (adjusted value up) or [VOL
9)Press the X key to write the adjusted value.
10)Select manual mode of the test mode, and set item number 772 (see page 14).
Set LCD display
772AD **
**: Adjusted value
11)Adjust with the [VOL +] key (adjusted value up) or [VOL
12)Press the X key to write the adjusted value.
13)Select manual mode of the test mode, and set item number 773 (see page 14).
Set LCD display
773AD **
**: Adjusted value
14)Adjust with the [VOL +] key (adjusted value up) or [VOL
15)Press the X key to write the adjusted value.
16)Select manual mode of the test mode, and set item number 774 (see page 14).
Set LCD display
774AD **
**: Adjusted value
17)Adjust with the [VOL +] key (adjusted value up) or [VOL
18)Press the X key to write the adjusted value.
19)Select manual mode of the test mode, and set item number 775 (see page 14).
Set LCD display
775AD **
**: Adjusted value
20)Adjust with the [VOL +] key (adjusted value up) or [VOL
21)Press the X key to write the adjusted value.
22)Select manual mode of the test mode, and set item number 776 (see page 14).
Set LCD display
776AD **
**: Adjusted value
20