Sony MX-E501 service manual Section Electrical Adjustments, Manual Power Adjustments, Reset NV

Page 12

MZ-E501

SECTION 5

ELECTRICAL ADJUSTMENTS

5-1. GENERAL

In this set, CD and MO discs can be automatically adjusted by setting the Overall Adjustment mode within the TEST MODE,

Before performing these automatic adjustments, it is necessary to clear the memory and adjust the power in the Manual mode.

5-2. NOTES FOR ADJUSTMENT

5-2-1. Jigs

 

CD disc

TDYS-1 (part code: 4-963-646-01)

MO disc

PTDM-1 (part code: J-2501-054-A)

 

 

or commercially available MO disc (recorded)

Digital voltmeter

5-2-2. Adjustment sequence

The adjustments should be always performed in the following sequence:

5-4. MANUAL POWER ADJUSTMENTS

5-4-1. Adjustment sequence

The adjustments should be always performed in the following sequence:

1Vc PWM Duty (L) adjustment (item No.:762)

r

2 Vc PWM Duty (H) adjustment (item No.:763) r

3 VLL PWM Duty adjustment (item No.:764)

5-4-2. Vc PWM Duty (L) adjustment method

1.

Confirm that the power voltage is at 1.5 V DC.

2.

Set the TEST MODE.

3.

To set the overall adjustment mode, press VOL– key.

1Reset NV (Clear the memory)

2Manual power adjustments

3Electrical offset adjustments (Do not enter the disc)

4Overall CD adjustments

5Overall MO adjustments

6RESUME clear

5-2-3. Power

Manual mode

Overall adjustment mode

Manual mode

LCD display

000 Assy 00

4.Press PLAY MODE key, and item No. will change to 762. LCD display

762 VclPWM XX

5. Connect a digital voltmeter to TP901 (VC) on the main board

and adjust VOL+ key (voltage up) and VOL– key (voltage

down) on the remote control.

The power is supplied with 1.5 V DC from the battery case.

5-3. RESET NV

5-3-1. How to reset NV

1.Set the TEST MODE.

2.Set the Manual mode and set the item No. 021, Reset NV. LCD display

021 Res NV CC

3.Press X key on the remote control. LCD display

021 Res OK?

4.Press X key on the remote control again. LCD display

021 Res ***

After reset is completed.

021Reset!

5.Press x key to terminate the Manual mode and return to the

TEST MODE.

Adjustment value:2.36V

Standard value:2.35 to 2.365V

MAIN BOARD (SIDE B)

digital voltmeter

TP901 (VC)

6.Press X key to write the adjustment value. Item No.will change to 763.

12

Image 12
Contents Specifications MZ-E501Table of Contents DisassemblyDiagrams Exploded ViewsSection Servicing Notes Section General Location and Function of Controls GroupSection Disassembly Case ASSY, Holder AssyMechanism Deck Bracket AssyMain Board Optical PICK-UP Assy LCX-4ESection Test Mode Setting the Test ModeGeneral Manual Mode Overall Adjustment ModeHow to set the Manual mode SELF-DIAGNOSTIC Display Mode Self-diagnostic modeKEY Check Mode Sound Skip Check Result Display ModeSetting the Key Check mode EIBSection Electrical Adjustments Manual Power AdjustmentsReset NV Vc PWM Duty H adjustment method Electrical offset adjustment methodOverall CD and MO adjustment method Overall CD and MO adjustment items Resume clear methodMZ-E501 Section Diagrams WaveformsBlock Diagram Main BoardPrinted Wiring Board Main Section Side a SemiconductorPrinted Wiring Board Main Section Side B Side BOprledgh MZ-E501 2222 IC Block Diagrams IC301 TA2131FL ELIC901 XPC18A32FCR2 IC PIN Function Description Oprledgl XtestOprledrl MIFVSS3AVS2 Avss APCDSPVDD0 DSPVSS0DSPVDD2 DSPVSS1Spcu SpcvTEST1, TEST0 SSB CLKMCUVSS0 VL PWMLCD STB LCD RSTREC LED TSB SLV CHKSection Exploded Views Main SectionMechanism Section 5961Electrical Parts List Main SectionXPC18A32FCR2 Ver 1.1 Memo MZ-E501 How to distinguish the sets Before change After change¥ Signal path Main Board Main Board + Line Tantalums Schematic Diagram Main /3 See page 9 for IC Block Diagrams IC Block Diagrams IC901 XPC18A32FCR2 Signal C input from the optical pick-up detector IC601 CXD2671-207GA System Control AVS2 Avss DSPVDD2 188,189 Not used open 190 LCD STB 1uF 10% C102 126-246-11 IC XPC18A32FCR2 SWITCH, Tactile VOL− Revision History Ver Date Description of Revision