Sony MX-E501 service manual Manual Mode, Overall Adjustment Mode, How to set the Manual mode

Page 9

MZ-E501

4-4. MANUAL MODE

4-4-1. Outline of the function

The Manual mode is designed to perform adjustments and operational checks on the set’s operation according to each individual function.

Usually, no adjustments are made in this mode.

However, the Manual mode is used to clear the memory before performing automatic adjustments in the Overall Adjustment mode.

4-4-2. How to set the Manual mode

1.Set the TEST MODE and press VOL+ key to set the Manual mode. Remote control LCD display

000Manual

2.During each test, press and hold down > N key or . key for a while to move the optical pickup on the sled outer or inner perimeter.

3.Each test item is assigned with a three-digit item number. The 100th place is a major item, 10th place is a middle item, and unit place is a minor item.

4.During each test mode, the display is changed from one to another each time DISPLAY key is pressed.

Address & Adjusted Value Display LCD display

011C68S5E

adress

adjusted value

mode number

Jitter Value & Adjusted Value Display LCD display

011OFEJ5E

jitter value

adjusted value

mode number

Block Error Value & Adjusted Value Display LCD display

011063B5E

Change Major

Item

 

 

 

 

 

 

 

 

 

 

key

 

x key

 

 

 

 

 

> N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change Middle

 

 

 

Item

 

 

 

 

 

 

key

 

x key

 

 

 

 

 

> N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change Minor

 

 

 

 

Item

 

 

 

VOL+ key : 100th place of mode number increase

VOL– key : 100th place of mode number decrease

VOL+ key : 10th place of mode number increase

VOL– key : 10th place of mode number decrease

>N key : Unit place of mode number increase

.key : Unit place of mode number decrease

 

 

 

 

 

adjusted value

block error value

mode number

ADIP Error Value & Adjusted Value Display LCD display

011072A5E

 

 

 

 

 

adjusted value

ADIP error value

mode number

Focus Drive Voltage Value & Adjusted Value Display

011000F5E

 

 

 

 

 

adjusted value

forcus

 

drive

 

voltage value

 

Change Adjustment

VOL+

key : Up

Value

 

key : Down

VOL–

Write Adjustment

Value

Xkey : When adjusted value is changed : Adjusted value is written.

When adjusted value is not changed : That item is adjusted automatically.

mode number

Item Title Display LCD display

011 LrefPw 5E

item

 

title

adjusted value

 

mode number

Note: In the Power mode, the item title display is only displayed.

5.To terminate the Manual mode and return to the TEST MODE, press x key.

4-5. OVERALL ADJUSTMENT MODE

4-5-1. Outline of the function

This mode is designed to adjust the servo system automatically by going through all the adjustment items.

The power adjustment manual setting is performed in this mode also. Usually, this mode is used to perform automatic adjustments when servicing the set.

For further information, refer to section 5. ELECTRICAL ADJUSTMENTS. (See page 12)

9

Image 9
Contents MZ-E501 SpecificationsDisassembly Table of ContentsDiagrams Exploded ViewsSection Servicing Notes Location and Function of Controls Group Section GeneralCase ASSY, Holder Assy Section DisassemblyBracket Assy Mechanism DeckOptical PICK-UP Assy LCX-4E Main BoardSection Test Mode Setting the Test ModeGeneral Manual Mode Overall Adjustment ModeHow to set the Manual mode Self-diagnostic mode SELF-DIAGNOSTIC Display ModeSound Skip Check Result Display Mode KEY Check ModeSetting the Key Check mode EIBSection Electrical Adjustments Manual Power AdjustmentsReset NV Vc PWM Duty H adjustment method Electrical offset adjustment methodOverall CD and MO adjustment method Resume clear method Overall CD and MO adjustment itemsMZ-E501 Waveforms Section DiagramsMain Board Block DiagramSemiconductor Printed Wiring Board Main Section Side aSide B Printed Wiring Board Main Section Side BOprledgh MZ-E501 2222 IC301 TA2131FL EL IC Block DiagramsIC901 XPC18A32FCR2 IC PIN Function Description Xtest OprledglOprledrl MIFVSS3APC AVS2 AvssDSPVDD0 DSPVSS0DSPVSS1 DSPVDD2Spcu SpcvSSB CLK TEST1, TEST0MCUVSS0 VL PWMLCD RST LCD STBREC LED TSB SLV CHKMain Section Section Exploded Views5961 Mechanism SectionSection Electrical Parts List MainXPC18A32FCR2 Ver 1.1 Memo MZ-E501 Before change After change How to distinguish the sets¥ Signal path Main Board Main Board + Line Tantalums Schematic Diagram Main /3 See page 9 for IC Block Diagrams IC Block Diagrams IC901 XPC18A32FCR2 Signal C input from the optical pick-up detector IC601 CXD2671-207GA System Control AVS2 Avss DSPVDD2 188,189 Not used open 190 LCD STB 1uF 10% C102 126-246-11 IC XPC18A32FCR2 SWITCH, Tactile VOL− Ver Date Description of Revision Revision History