TEST MODE
Note: Information on the test mode must correspond in enough security. When the leakage has been revealed by any chance, the source of information is specified.
1. SETTING THE TEST MODE
Note: Perform the test mode in the state of 3.6 V or more in the battery voltage.
Setting method:
1.Turn the power on.
2.Press the [BACK] key for 1.5 seconds or more, the home menu is displayed.
3.Slide the [HOLD] key to set the hold on.
4.While pressing the [OPTION] key, press the key as following
order.
[v] → [v] → [V] → [V] → [B] → [b] → [v] → [V] → [v] →
[V] → [B] → [u]
5.The set reboots when the [HOLD] key is slided to set the hold off, and the color bar is displayed in the liquid crystal display.
6.Enter the test mode when the [BACK] key is pressed in the
state of step 5.
Note: The destination setting and sound pressure regulation setting can- not be executed by this test mode.
2. RELEASING THE TEST MODE
1.Display the major item selection screen.
2.Press the [v]/[V] key to select the “EXITTEST”, and press the [B] key to select the “SURE ?”.
3.Press the [u] key, turn the power off and release the test mode.
3.CONFIGURATION OF THE TEST MODE
4-1-1. Power supply voltage check
This mode is used in case power supply voltage in the state where all power supply lines are starting is checked.
Checking method:
1.Enter the test mode.
2.Press the [v]/[V] key to select the “POWER”, and press the [B] key to enter the minor item.
3.Press the [v]/[V] key to select the “VCHK”.
4.Press the [u] key, all power supply lines are started.
liquid crystal display
POWER VCHK
START
In this state, the power supply voltage of each power supply line can be confirmed by measuring the voltage.
5. Press the [BACK] key, return to minor item selection screen.
Major item
<#> key |
| <C> key |
|
|
|
Minor item
Major item switching: <W>/ <7> key
Minor item switching: <W>/ <7> key
Checking method:
1. | Enter the test mode. |
2. | Press the [v]/[V] key to select the “POWER”, and press the |
<V>key
Start
Automatic
Finish
or
Result
<#"$,> key
| [B] key to enter the minor item. |
3. | Press the [v]/[V] key to select the “ACHK”. |
4. | Press the [u] key, “1 kHz 0 dBs |
| audio signal is outputed. |
liquid crystal display
4.OPERATION OF THE TEST MODE 4-1. Power
liquid crystal display
MPTAPP MENU
POWER VCHK
AUDIO ACHK
VIDEO DSVCHK
OTHER CHGCHK
CLESTE BATTCHK
DAC
BLUETOOTH
SHUTDOWN
EXITTEST
POWER ACHK
1kHz 0dBs L/Rch HPOUT [ VOL: 15 ]
START
5.In this state, each time the [OPTION] key is pressed, LCD back light on/off switch is performed.
6.Press the [BACK] key, return to minor item selection screen.