Furuno FS-1503 manual Remote Station RB-500, Distributor DB-120/DB-500, Necessary parts

Page 19

3.3 Remote Station RB-500

Connect to the REMOTE connector on the FS-1503. If more than two RB-500s or DSC, NBDP are to be installed, connect them via the Distributor DB-500.

Necessary parts

Requires REMOTE-B Kit (current loop) for connection of a single remote station or REMOTE- A Kit when the DB-500 is connected. Install the board following the illustration on page 3-3.

Contents of REMOTE-B Kit OP05-83 (Code no. 005-939-820)

Name

Type

Code No.

Qty

 

 

 

 

REMOTE PCB

05P0458

005-840-990

1

 

 

 

 

Connector Assy.

05S0928

000-130-440

1

(REMOTE connector)

 

 

 

 

 

 

 

3.4 Distributor DB-120/DB-500

A distributor enables connection of multiple external equipment. The DB-120 connects one NBDP Terminal and one DSC Terminal, and the DB-500 connects up to four external equip- ment: one NBDP terminal, one DSC terminal, and two remote stations. In either case the RE- MOTE-A board is also required.

SSB

DISTRIBUTOR

DB-500

NBDP TERMINAL

DSC TERMINAL

REMOTE STATION

REMOTE STATION

Figure 3-2 Function of the Distributor DB-500

3-2

Image 19
Contents Page B . N o . I M E 5 6 1 4 0 E Safety Instructions Table of Contents Standard Set Equipment ListsFAW-6RP2A Optional EquipmentFS-1503 System Configuration System ConfigurationMounting on overhead, bulkhead or tabletop MountingMounting of Transceiver Unit General mounting considerationsMounting considerations Console mountingMounting considerations Mounting of Antenna CouplerMounting methods Mounting the antenna couplerHow to mount the antenna coupler Grounding the transceiver unit Ground SystemGround for metallic hull Ground for non-metallic hullAbout antennas Mounting of AntennaLong wire antenna Whip antenna Typical antenna installationsRED BLK WiringConnections inside the antenna coupler Remarks on connection Wiring of Optional EquipmentNbdp Terminal DP-6 DSC Terminal DSC-60Distributor DB-120/DB-500 Remote Station RB-500Necessary parts Remote and Control Boards Unplug all connectors from TX/RX Board dismount the boardTelex Filter Bandpass Filter BK Break-in ConnectionPA/FIL Board SW Regulator SW REG boardDummy Load W4 Wire Assy W3 Wire AssyConnection of floating ground radiotelephone Floating Ground Radiotelephone FS-5000, etcSupply voltage Installation CheckLnstallation Checks Visual checksPerformance User Channel RegistrationNoise Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page