MAINTENANCE AND TROUBLE-SHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department toll- free at
PROBLEM: The power does not turn on
SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppres- sor is plugged into a properly grounded outlet (see page 7). Use only a
b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.
C.Check the circuit breaker located on the treadmill
C
frame near the power cord. If the switch protrudes
as shown, the circuit breaker has tripped. To reset TrippedReset the circuit breaker, wait for five minutes and then
press the switch back in.
PROBLEM: The power turns off during use
SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing above), tf the circuit breaker has tripped, wait for five minutes and then press the switch back in.
b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.
c. Make sure that the two wires under the console are fully plugged in. (Refer to assembly step 3 on page 6. WARNING: Do not disconnect or connect the wires while the treadmill power cord is plugged in.)
d. Remove the key from the console. Reinsert the key fully into the console.
e. If the treadmill still will not run, please call our Customer Service Department,
PROBLEM: The displays of the console do not function properly
SOLUTION: a. Check the batteries in the console. If the batteries need to be replaced, see BATTERY INSTALLATION on page 8. Most problems are the result of drained batteries.
b.Remove the screws from the hood, and carefully remove the hood. Locate the Reed Switch (13) and the Magnet (63) on the left side of the Pulley (75). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that there is a gap of about 1/8" between the Magnet and the Reed Switch. If necessary, loosen the Screw (31) and move the Reed Switch slightly. Retighten the Screw.