Newcon Optik LRB 20000 Principles of Work, Problem Probable reason Solution Description

Page 14

5. PRINCIPLES OF WORK

5.1.The LRB 20000 assembly (Fig.1) consists of rangefinder 1 mounted on the angular mount 2. The latter is mounted on the tripod 3.

5.2.Rangefinder (Fig.2) is designed for terrain observation and measuring the distance to the closest or next-in range target caught in the beam. It works with the principle of measuring the light pulse round-trip time. The measurement result is displayed in meters on digital range indicator and can be also stored in the computer for further calculations.

The schematic circuit diagram of range finder (Fig.3) shows rechargeable battery (G1), controls switches (S1- S4), pumping and firing elements (ref. designations C1-C3, E1, L1, T1, V1- V2), control circuit board (A1), display circuit board (A2), counter circuit board (A3), and photodetector assembly (A4). Toggle switch S1 is operated to energize the range finder, and toggle switch S4 – to light up the light-emitting diode (LED) H1 which illuminates the reticle pattern.

Button switches S2 and S3 labeled (MEASURE 1) and (MEASURE L) respectively are used to prepare the rangefinder for taking a measurement (by pressing one of those buttons). Button S2 is operated to range the closest target, whereas button S3 is used to engage the next-in-range target caught in the beam.

11.2.The possible problems with the rangefinder are listed below in Table 11.1

 

 

Table 11.1

Problem

Probable reason

Solution

description

 

 

1. Picture is blurred

Condensed moisture,

Clean exterior of optical

in the right-hand

dirt on external

parts as directed under

eyepiece

optical surfaces

10.6.2

 

Condensed moisture

Dry rangefinder as

 

on internal optical

directed under 10.6.3

 

surfaces

 

2. Readiness

Open circuit in the

Clean contacts as

indicator remains

battery section (when

directed under 10.6.1

dark after

standard battery is

 

MEASURE 1

used)

Replace fuse as directed

(MEASURE L)

Blown fuse in the

button release

protection device

under 11.3.1

 

(when vehicle

 

 

electrical system is

 

 

used)

Clean contacts as

 

Open circuit in

 

battery section (when

directed under 10.6.1

 

vehicle electrical

 

 

system is used)

 

3. Red Low Battery

Unallowably low

Replace the battery with

indicator is on

battery voltage

a newly charged one as

 

 

directed under 11.3.2

Image 14
Contents Long Range Laser Range Finder Acceptance Certificate Laser Rangefinder LRB20000Important Information Customer SupportFeatures of the LRB 20 000 Laser Range Finder Binocular WarrantyTable of Contents Overview Data Output to External Equipment To secure trouble-free operation of the rangefinder Never Rechargeable Battery HandlingAbbreviations Technical Characteristics ShipmentStorage Rules Parameter Ambient temperatureLong Term Storage Pumping voltage UpumpDesignation Supplied AccessoriesDescription Qty Serial50 g Problem Probable reason Solution Description Principles of WorkTroubleshooting Page Materials, tools and accessories Safety PrecautionsProcedure as per OperationsOperations Procedure as Per Accessories NeverNever disassemble the rangefinder yourself SET Selector to OFF Before Replacing the Battery Preparing for USEMaintenance Items to check, test procedure Technical requirementServiceability Test Page Page Operating Procedure Binoculars rangefinder unit LRB 20000 in packing case Individual Spta set Laser rangefinder binoculars LRB Tripod mount Angular Mount Rangefinder rear view Schematic diagram