Newcon Optik PHANTOM 20 operation manual

Page 12

-As the readiness indicator comes on, aim the range finder at an off-set point forward of the target;

-As the target aligns with he reticule gap, release the MEASURE 1 (MEASURE L) button;

-Read the measured range.

8.5.To take azimuth and magnetic azimuth measurements, proceed as follows:

- Align the vertical mark of the Binocular objective reticule with the right-hand object;

- Read and note down the azimuth dial indication accurate to 1/10 of a division on the vernier;

- Align the vertical mark of the reticule with the left-hand object and read the angle again;

- Determine the measured angle.

Measure the angle by subtracting the latter value from the former one. Add 60.00 mils to the former value if exceeded by the latter one.

During the magnetic orientation of the range finder, the angles read off the azimuth dial are the magnetic azimuth values (bearings) of the target (or reference object).

The magnetic azimuth correction is to be inserted (see under

7.5.3.).

If the measurement has to be precise, take 3 or 4 angle measurements to calculate the mean value. After each measurement of the magnetic azimuth value (bearing), upset the range finder orientation and change the azimuth dial reading.

An azimuth or magnetic azimuth measuring under 0.80 mils may be read off the reticule with a maximum accuracy of 0.05 mils (small division value of the reticule is 0.05 mils, large division value is

0.10mils).

8.6.To measure vertical and elevation angles, proceed as follows:

-Align the horizontal mark of the range finder Binocular reticule with the upper object;

-Read the vertical angle scale using the vernier and note down the reading;

-Rotate the azimuth and elevation knobs to align the horizontal mark of the reticule with the lower object and read the scale again;

-Determine the vertical angle by subtracting the smaller value from the greater one if both have the same sign (are of the same color), or by adding them, if the signs are opposite.

The elevation is measured with reference to the Binocular axis of the range finder. Hence, the range finder should be thoroughly leveled before taking the elevation measurements.

Vertical angles up to 0.80 mils and elevation angles falling within ± 0.40 mils may be read off the reticule with a maximum accuracy of 0.05 mils.

8.7.To determine the polar coordinates, proceed as follows:

-Use the compass to orient the Angular Mount as directed under 7.5.3;

-Binocular the range finder on the object;

-Read the azimuth of the object;

-Range the object as directed under 9.3.

8.8.To convert the polar coordinates into rectangular coordinates, proceed as follows:

- Remove the coordinate converter from the case;

- Release the clamp and detach the rule from the reverse side of the plotting board;

- Determine the polar coordinates of the reference point and the target as directed under 9.7 and note them down on the plotting board or a special card;

Image 12
Contents LRB 20 Contents Following abbreviations are used herein Technical Characteristics PurposeSupplied Accessories EmitterAppearance of the Device Page Safety Precautions NeverBefore Replacing BATTERY, SET Selector to OFF Preparing for USEPage Operating Procedure Page = Am ∆ Am Serviceability Test MaintenanceSurfaces Servicing within Trouble Shooting Measure Long Term Storage Storage RulesRechargeable Battery Handling ShipmentPage Data Output to External Equipment Acceptance CertificateLong Term Storage Certificate Packing CertificateWarranty Customer SupportPage Tripod mount Angular Mount Binoculars range finder unit LRB 20 Packing case AEP