9. SERVICEABILITY TEST

The principal tests to be performed on the range finder are listed below. Table 9.1

What is checked, tools, instruments,

 

Technical requirement

equipment. Test procedure

 

 

1. Range finder completeness

 

Range finder is complete with all

 

 

 

 

components listed in Section 5

2. Range finder exterior

Exterior surfaces are clean and free

 

 

 

 

from cracks, dents and rust

3.Exterior

of

range finder optical

Optical surfaces are free from

parts (to be checked visually). Make

cracks, scratches, chips, dirt, grease

sure the unit is off!

stains (on exterior) and condensed

 

 

 

 

moisture (inside)

4. Dehydrator case of range finder ( to

Silica gel is bluish in colour

be checked visually)

 

5.Battery voltage. Proceed as directed

Red glow not observed in left

under 8.3.1.

 

 

eyepiece of range finder

6. Illumination of range finder Binocular

Binocular reticule is illuminated

reticule. Check that front cover is

 

closed on range finder and set ILLUM.

 

selector switch to ON

 

7.Functioning of range finder. Proceed

Measurement results are within 5 m

as directed under 8.3.2.

of predetermined range or on

8. Setting

of

zero elevation reference

another ER “O” error determined for

vertical angle scale is to be

(ER “0”). Proceed as under 8.6.1.

reckoned in while measuring target

 

 

 

 

 

 

 

 

elevation

 

Table 9.1, continued

 

 

What is checked, tools, instruments,

Technical requirement

equipment. Test procedure

 

 

 

9. Sensitivity, indexing uniformity

Turn in unit for repair if even a

and balance of magnetic needle.

single requirement of 8.6.2. is

Proceed as under 8.6.2.

not satisfied

10.AI azimuth and elevation If necessary, tighten bushings on

adjustment knobs for play

knob end faces to eliminate play

10.MAINTENANCE

10.1.Maintenance Organization and Procedure. General

Instructions.

10.1.1.This Section deals with the maintenance services prescribed for the range finder, excepting the battery servicing procedure. For the latter procedure, refer to Section 16.

10.1.2.The range finder is serviced to ensure its operability and readiness for operation.

The range finder is subject to timely full-scope servicing, unless premature wear should occur resulting in shorter periods between repairs.

10.1.3.While preparing for and caring out the maintenance services, observe the safety precautions as outlined in Section 6.

Image 14
Contents LRB 20 Contents Following abbreviations are used herein Technical Characteristics PurposeSupplied Accessories EmitterAppearance of the Device Page Safety Precautions NeverBefore Replacing BATTERY, SET Selector to OFF Preparing for USEPage Operating Procedure Page = Am ∆ Am Serviceability Test MaintenanceSurfaces Servicing within Trouble Shooting Measure Long Term Storage Storage RulesRechargeable Battery Handling ShipmentPage Data Output to External Equipment Acceptance CertificateLong Term Storage Certificate Packing CertificateWarranty Customer SupportPage Tripod mount Angular Mount Binoculars range finder unit LRB 20 Packing case AEP