TYPICAL PRODUCT PARAMETERS

Mechanical Parameters

 

MA90Z

 

MA95Z

 

 

 

 

CONTROL UNIT DIMENSIONS (L X W X H):

 

 

 

 

15” x 6½” x 11”

 

 

 

CONTROL UNIT WEIGHT:

 

15 lbs

 

 

CONTROL UNIT POWER CORD:

10 - 14 Feet Long, Hospital Grade

 

 

 

 

CONTROL UNIT CONNECTION:

Quad Flow - Four ¼”

 

Triple Flow - Two ½” and

 

Single Quick Coupling

 

One ¼” Single Magnetic

 

 

 

Quick Coupling

 

 

 

CONTROL UNIT PACKAGING:

1 piece/box

 

 

 

 

AIR FILTER:

None

 

Charcoal Air Filter with

 

 

 

Fire Retardant

 

 

 

 

Environmental Parameters

 

MA90Z/MA95Z

 

 

OPERATING CONDITIONS

 

AMBIENT TEMPERATURE:

50° - 95° F

RELATIVE HUMIDITY:

30% - 75% Non-Condensing

ATMOSPHERIC PRESSURE:

70 - 106 kPa

 

 

STORAGE AND SHIPPING CONDITIONS

 

AMBIENT TEMPERATURE:

-40° - 158° F

RELATIVE HUMIDITY:

10% - 100%

ATMOSPHERIC PRESSURE:

50 - 106 kPa

 

 

MA90 Series

6

Part No 1148139

Image 6
Contents MA90 Series Special Notes Special NotesMeaning Table of Contents Table of Contents Register Your ProductPerformance Parameters Typical Product ParametersElectrical Parameters Typical Product ParametersMechanical Parameters Environmental ParametersLabel Location Label LocationContraindications InstallationGeneral Guidelines Entrapment May OccurSmoking Fire HazardElectrical Anesthesia EquipmentInstalling the Mattress Replacement System OperationOperation Installing the Side Rails Installing the Power Unit Installing the Mattress Replacement SystemConnecting the Hose Connecting the Power Cord Connecting the HoseUsing the Front Panel Power ButtonTurn Angle Button MA90Z Turn Button MA90ZTurn Time Button MA90Z Rotation Button MA95ZFirm/Soft Buttons Automatic Wireless FowlerHold Button MA95Z Operation Function DescriptionProgramming the Automatic Wireless Fowler Transmitter Mode Button MA90Z Max Inflate Button MA95ZPower Fail LED Powering Up the SystemLock/Alarm Silence Button Low Pressure LEDPlacing the Patient on the Mattress Transferring Patient From/To a GurneyPreparing for CPR Procedure Transferring Patient From/To a WheelchairPreparing for CPR Procedure Maintenance and Troubleshooting Cleaning the SystemMaintenance and Troubleshooting Storing the System Troubleshooting Problem Cause SolutionChanging the Filter Maintenance and Troubleshooting Problem Cause Solution Maintenance and Troubleshooting Limited Warranty USA