Star Trac E-TRE, E-TRXE manual Trouble Shooting, Error Name Description Diagnosis Code

Page 39

Trouble Shooting

All Embedded Display Products perform a self-test at the beginning of every workout. If a problem is detected, a mes- sage displays before or after the workout, depending on the nature of the problem. Star Trac recommends that you refer your questions about your STAR TRAC PRODUCTS operation and suspected malfunctions to Star Trac’s Service Hot- line at (800) 503-1221, or USA 1-714-669-1660.

The following messages are displayed at the beginning of a workout if the associated problem is detected during self-test (codes used in the FIT_ERROR and DISP_ERROR commands). For Treadmills xCB is the Translator Board and For Bikes, TBTs and Steppers it is the LCB Board.

ERROR

NAME

DESCRIPTION

 

DIAGNOSIS

 

CODE

 

 

 

 

 

4

Timeout waiting

This is reported when the

1.

Re-boot the unit and see if the problem goes away.

 

 

for query ID re-

Sidcup does not receive a

2.

If the problem persists, check the communications

 

 

sponse from

query id response from the

 

cable Between the Sidcup and the Display.

 

 

display.

display during boot up.

3.

If the problem still persists change the communica-

 

 

 

 

 

tions cable.

 

5

No query id

This is reported when the

1.

Re-boot the unit and see if the problem goes away.

 

 

response re-

Sidcup does not receive a

2.

If the problem persists, check the communications

 

 

ceived from dis-

query id response from

 

cables between the Sidcup and the Display and cob.

 

play or X-C.

both the display and cob

3.

If the problem still persists change both of the com-

 

 

 

during boot up.

 

munications cable.

 

6

Timeout waiting

This is reported when the

1.

Re-boot the unit and see if the problem goes away.

 

 

for query ID re-

Sidcup does not receive a

2.

If the problem persists, check the communications

 

 

sponse from X-

query id response from the

 

cable between the Sidcup and the cob.

 

 

C.

cob during boot up.

3.

If the problem still persists change the communica-

 

 

 

 

 

tions cable.

 

14

Timeout waiting

This is reported when the

1.

Re-boot the unit and see if the problem goes away.

 

 

for query id re-

display does not receive a

2.

If the problem persists, check the communications/

 

 

sponse from

query id response from the

 

power cable between the Display and the COB.

 

 

COB.

COB during boot up.

3.

If the problem still persists change the communica-

 

 

 

 

 

tions/power cable.

 

 

 

 

 

 

 

21

Timeout waiting

This is reported when the

1.

Re-boot the unit and see if the problem goes away.

 

 

for query ID

display times out waiting for

2.

If the problem persists, check the communications

 

 

from Sidcup.

a query id command from

 

cable between the Display and the Sidcup.

 

 

 

the Sidcup during boot up.

3.

If the problem still persists change the communica-

 

 

 

 

 

tions cable.

 

 

 

 

4.

If the problem still persists change the Sidcup board.

22

Timeout during

This is reported when the

1.

Re-boot the unit and see if the problem goes away.

 

 

start-up hand

display times out waiting for

2.

If the problem persists, check the communications

 

 

shaking.

a go to idle command from

 

cable between the Sidcup and the cob. Also check the

 

 

the Sidcup during boot up.

 

communications cable between the Display and Sid-

 

 

 

 

cup.

 

 

 

 

3.

Check the error code that is being flashed on the Sid-

 

 

 

 

cup. It may be different than the one being displayed

 

 

 

 

on the display. Check this error code in the error

 

 

 

 

 

codes table.

 

 

 

 

4.

If the problem still persists change both of the commu-

 

 

 

 

nications cable.

 

23

Fit CPU watch-

This is reported when there

1.

Re-boot the unit and see if the problem goes away.

 

 

dog response

is no communication be-

2.

If the problem persists, check the communications

 

 

timeout.

tween the display and the

 

cable between the Sidcup and the Display.

 

 

 

Sidcup for more than 2 sec-

3. If the problem still persists change the communica-

 

 

 

onds.

 

tions cable.

 

38

Incline calibra-

Fit CPU reports MOB error

1.

Re-boot the unit and see if the problem goes away.

 

 

tion value out of

status:

2.

If the problem persists, check the Product Model in

 

 

range

Incline calibration value out

 

Maintenance Mode and ensure it is correct.

39

 

 

of range

3.

Re-calibrate the Incline.

 

 

 

 

 

 

 

 

 

Image 39
Contents Models Page Corporate Headquarters Page Table of Contents FCC Regulatory InformationStar Trac Embedded Display Console Specifications Getting StartedIntroduction Important Safety Instructions Safety InstructionsEmbedded Display Console Display ConsoleHome Screen Center Console Keypad Treadmills Safety Stop Assembly & Product Model Setup AssemblySetup Page Quick Start Operation InstructionsPreset Programs Preset Programs Bikes Preset Programs Total Body Trainer Preset Programs Stepper Page Advanced Workout Programs Program Description Workouts DefinitionsTreadmills Bikes Famous Italian Leaning Tower of Pisa 293 steps Heart View Workout Views TreadmillSimple View Track ViewWorkout Views TBT Upper Body Positions Cooldown Cycle TV Functions IPod Media Center USB Media Center Additional Features Using Personal FansHeart Rate Monitoring User Detect Lock OUTService Menu Manager Mode Diagnostics ModeUsage Statistics Calibration and Setup Page Daily Maintenance Preventative MaintenanceError Name Description Diagnosis Code Trouble ShootingError Name Description Diagnosis Code Page Expect different