Read the Operation Manual before setting up the Life Fitness Treadmill. Place the treadmill where it will be used before begin- ning the setup procedure.

ELECTRICAL POWER REQUIREMENTS

The Life Fitness Treadmill requires a dedicated* line according to the elec- trical configurations listed in the chart below.

* One individual branch circuit for each treadmill per NEC article 210-21 (b) (1) and 210- 23 (or other appropriate, country specific electrical compliance guidelines). The hot, neu- tral and ground wires must each be routed independently (not looped or tied to other cir- cuits.)".

NOTE: Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet, have a proper outlet installed by a qualified electrician.

GROUNDING INSTRUCTIONS

This Life Fitness product must be properly grounded. If the unit malfunctions or breaks down, proper grounding provides a path of least resistance for the electric current, which reduces the risk of shock to anyone touching or using the equipment. Each unit is equipped with an electrical cord, which includes an equipment grounding conductor and a grounding plug. The plug must be inserted into an outlet that has been properly installed and grounded in accordance with all local codes and ordi- nances.

A temporary adapter MUST NOT BE USED to connect this plug to a two-pole receptacle in North America. If a properly grounded, 20-amp outlet is not available, one must be installed by a qualified electrician. Models drawing 16 amps or more must be installed on a dedicated line.

IL EST ABSOLUMENT INTERDIT d'employer un adaptateur temporaire pour brancher cette fiche sur une prise bipolaire en Amérique du Nord. Si aucune prise de 20 A correctement mise à la terre n'est disponible, en faire installer une par un électricien qualifié. Les modèles utilisant 16 A ou plus doivent être branchés sur un circuit spécialisé.

DANGER: A risk of electrical shock may result from improper connection of the equipment-grounding conductor. Check with a qualified electrician if in doubt as to proper grounding technique. DO NOT modify the plug provided with the product. If it will not fit an electrical outlet, have a proper outlet installed by a qualified electrician. Any modification to the electrical plug will result in a voided warranty.

DANGER:Un branchement incorrect du conducteur de mise à la terre peut entraîner des risques de décharge électrique. Consulter un électricien si des doutes subsistent quant à la technique de mise à la terre. NE PAS MODIFIER la fiche fournie avec l'appareil. Si elle ne s'adapte pas à une prise, faire installer une prise correcte par un électricien qualifié. Toute modification à la fiche annule la garantie.

9

Image 10
Contents 95T Treadmill Base Corporate Headquarters International OfficesPage Table of Contents 95T Important Safety Instructions LocationOperation Consignes DE Sécurité Importantes EndroitConserver CES Instructions Pour LE Consulter À Lavenir FonctionnementElectrical Power Requirements SetupGrounding Instructions Power Switch HOW to Position and Stabilize the Life Fitness TreadmillCentering the Belt Stride Sensor AUTO-SHUTOFF System Cable TV HOOK-UPPower Cord Routing Service and Technical Data Preventive Maintenance TipsPreventive Maintenance Schedule Display Console / Activity Zone AssemblyTroubleshooting the Treadmill Malfunction Probable Cause Corrective ActionMalfunction Probable Cause Corrective Action Troubleshooting the Treadmill Belt Tensioning Bolts Troubleshooting the Lifepulse System SensorsHOW to Adjust and Tension the Striding Belt Tracking Centering a Striding BeltProactive Belt Wear Notification HOW to Obtain Product ServiceTo Check for Notifications Specifications Life Fitness 95T Treadmill Base SpecificationsLife Fitness World Headquarters