Cateye MSC-2Dx Lap Feature, Recording Lap Data, Lap Data Read Out, Downloading Lap Data

Page 15

LAP

LAP

START

 

0.00.00

 

TM

LP-01

LP-02

LP-03

Lap interval longer than 5 sec. Up to about 27 hrs.

Lap Feature

Up to 50 lap data points can be captured (Elapsed Time, Average Heart Rate for the lap, [Average Speed for the lap] and Trip Distance) and stored in memory for manual review or downloading to a PC with an interface unit.

Recording Lap Data

LAP

In any of the main or sub functions, push the LAP button. The beep sound goes off and the lap data is saved. At the same time, the lower display indicates the current lap number for about 3 seconds.

NOTE !: You must wait a minimum 5 seconds before recording next lap. The maximum measurable time is 27 hours and 46 minutes.

‘Beep’

Because the lap data captured is the average heart rate and average speed for the

 

 

interval, short lap intervals may produce inconsistent data.

Lap number display for 3 sec. NOTE !: Lap data can be recorded even if Elapsed Time TM is not running (=stop state). However, once you record the lap data in the Stop State, next lap data cannot be recorded unless current speed gets started. The reset operation erases all lap data points.

 

Lap Data Read Out

 

To review the lap data:

 

TM

Elapsed Time is not running. (=stop state)

 

STOP

 

1. Navigate to where the Lap Count LP is in the lower display.

SET/AT

2.

Push SET/AT button.

 

The lap number is shown in the lower display for 1 second, and the screen starts to

 

MODE

 

readout the lap data.

 

 

Switching TM/DST

The upper display indicates Average Speed, the middle display indicates Average Heart Rate

 

LAP

and the lower display indicates Elapsed Time with the flashing TM icon. To switch the lower

 

 

display between Elapsed time TM and Trip distance DST, hold down the MODE button.

 

 

NOTE !: The data of heart rate and speed shown here is the average value of

Lap data readout screen

Downloading

the interval between the two points.

 

LAP

MODE

 

The next

 

lap data

SET/AT

 

If you hold down LAP button for 2 seconds, the unit starts to download the data and the readout screen is fast-forwarded automatically. The screen continues fast-forwarding until the download is finished.

3.Continue the readout.

Push LAP button to move to the next lap data. Push MODE button to return to the prior lap data.

NOTE !: Each lap number appears in the lower display for 1 second.

NOTE !: If you hold down LAP button, the unit starts downloading. If you have started to download by mistake, it can be stopped by pressing the Lap button again.

4.When you have finished reviewing the Lap data, push SET/AT button and the screen returns to the Lap Count LP display.

Downloading Lap Data

The recorded lap data can be downloaded to a PC through the optional interface unit and e-train data software. See the download manual for details.

MSC-2Dx 15

Image 15
Contents Introduction Quick Start manual Quick chart Inside Carry BagAbout the Manuals Meaning of icons in this manualContents Correct USE of the CAT EYE MSC-2Dx Chest Belt Heart Rate Sensor AccessoriesName of Various Sections and Parts Main UnitLap Button LAP Mode Button ModeButton Navigation SUB FunctionAll Clear Button AC Reset OperationSet Button SET/AT Start/Stop Button S/SFunctions Dst Trip Distance Lap CountAvS Average Speed MxS Maximum SpeedMaximum transmitting distance about 90 cm Using the Heart Rate FunctionChest Belt Heart Rate Sensor Before Wearing Chest Belt Heart Rate SensorWearing the Heart Rate Sensor Setting Wheel Circumference Setting the Main UnitChanging Wheel Circumferences Setting Clock TimeSwitching Between Wheel Circumference a and B Checking Wheel CircumferenceSpeed Pace Feature FeaturesAuto Time Feature Auto Start/Stop Power Saving FeatureDownloading Lap Data Lap FeatureRecording Lap Data Lap Data Read OutHeart Rate Target Zone Setting Heart Rate Target ZonesDownloading Time In Training Zone Setting Alarm SoundResetting Time In Heart Rate Zone Time In Heart Rate ZoneTake the following steps to record data to memory Procedure for Memory RecordIcon must be turned off Memory Record Interval SelectionCheck the Memory Record Files Icon must be offStop and Mode buttons simultaneously Setting up Memory RecordCanceling Memory Record Memory Record On/OffTurning off icon before timing starts Memory Record Data Review Download Memory Record DataStop Elapsed Time TM must not be running Stop-state Lap How to downloadDownloading to a PC Memory RecordFor improving your general fitness Heart Rate TrainingFor competitors Trouble Shooting Heart rate display occasionally reads zero Unit does not receive the heart rate signalYou cannot change the Interval Timer of memory record Clock setting screen does not appearCR2032 Replacing BatteryWireless Heart Rate Sensor Main UnitMaintenance Replacing Electrode BeltDaily Care of the MSC-2Dx Specifications Phone 303-443-4595 FAX RegistrationAccessories Replacement partOptional part Heart rate target Lap Index