SPECIFICATIONS

Display functions (Icon)

 

 

 

Range

Standard accuracy

 

Upper display

Current speed

 

 

0.0(3.0) - 65.9mph [0.0(4.0) - 105.9km/h]

± 0.5mph (under 31mph)

 

 

 

Clock time

1:00 - 12:59 [0:00 - 23:59]

± 0.003%

 

 

 

 

 

 

 

 

 

 

 

 

Speed icon

 

 

Illuminates when Current Speed is selected.

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock time icon

 

 

Illuminates when Clock Time is selected.

 

 

 

 

 

 

 

 

 

 

 

 

Center display

Heart rate

 

 

0 - 299 bpm

± 1bpm

 

 

 

 

 

 

 

 

 

 

 

Heart rate icon

 

Blinks when the heart rate signal is received.

 

 

 

 

 

 

 

 

 

 

 

Record memory icon

 

 

Illuminates when the record memory feature is activated.

 

 

 

 

 

 

 

 

 

 

 

 

Auto

icon

 

Illuminates when the Auto Time (automatic start/stop) feature is activated.

 

 

 

Alarm

icon

 

 

Illuminates when the alarm for heart rate target zone is operated.

 

 

 

 

 

 

 

 

 

Used memory icon

 

 

Illuminates when using record memory rate (%) is indicated on display.

 

 

 

Wheel circumference icon

 

 

Displays the wheel circumference currently active.

 

Lower display

Elapsed time

0:00'00" - 9:59'59"

± 0.003%

 

 

 

Maximum heart rate

 

 

0 - 299bpm

± 1bpm

 

 

 

Clock time

1:00 - 12:59 [0:00 - 23:59]

± 0.003%

 

 

 

Current speed

 

 

0.0(3.0) - 65.9mph [0.0(4.0) - 105.9km/h]

± 0.5mph (under 31mph)

 

 

 

Lap count

 

 

LP-00 - LP-50 (Lap Feature)

 

 

 

 

Average speed

 

 

0.0 - 65.9mph [0.0 - 105.9km/h]

± 0.5mph

 

 

 

 

 

 

 

 

 

 

 

 

Maximum speed

 

 

0.0(3.0) - 65.9mph [0.0(4.0) - 105.9km/h]

± 0.5mph (under 31mph)

 

 

 

 

 

 

 

 

 

 

 

Trip distance

 

0.00 - 999.99mile [km]

± 0.01mile (under 31mph)

 

 

 

 

 

 

 

 

 

 

 

Total distance

 

 

0.0 - 9999.9 / 10000 - 99999mile [km]

± 0.1/1mile (under 31mph)

 

 

 

 

 

 

 

 

 

 

 

Zone remaining time

0.00'00" - 9.59'59"

± 1"

 

 

 

 

 

 

 

 

 

 

Pace icon

 

Displays whether the speed is higher or lower than the average speed. (Pace Feature)

 

 

 

 

 

 

 

 

 

 

 

 

Additional features

Heart rate target zone

 

 

Heart rate range is divided into 4 zones and Time In Pulse Zone is measured and saved

 

 

 

 

 

 

 

(Alarm may be set in each zone).

 

 

 

 

Memory Record feature

 

 

Saves measurement data for 5 files or maximum 2,560 points (Memory Record Interval

 

 

 

 

 

 

 

timing may be selected from 5, 15, 30 or 60 sec.).

 

 

 

 

 

 

 

 

 

 

 

 

Lap feature

 

Saves for a maximum 50 points (Minimum interval: 5 sec.).

 

 

 

Others

 

 

Power saving feature (Auto reset upon receipt of speed sensor signal or forced reset by

 

 

 

 

 

 

 

button operation).

 

 

 

 

 

 

 

 

 

Download saved data to a PC (Optional download kit is required).*1

 

Control system:

 

 

 

 

 

4-bit one-chip microcomputer, crystal oscillator

 

 

 

 

 

 

 

 

 

Display system:

 

 

 

 

 

Liquid crystal display (equipped with the LED backlight)

 

 

 

 

 

 

 

 

Speed signal detection system:

 

 

Noncontact magnetic sensor

 

 

 

 

 

 

 

Heart rate signal transfer system:

 

Wireless signal simultaneous transfer (Transmission distance: Approx. 90 cm)

 

 

 

 

 

 

 

Operating temperature range:

 

 

32° F - 104° F [0° C - 40° C] (Can be used below 0°

with slower screen response.)

 

 

 

 

 

 

 

Storage temperature range:

 

 

–4°F - 122° F [–20°C - 50° C]

 

 

Wheel circumference set range:

 

10 - 3000mm / A/B switching method, initial value: A-2096, B-2050

 

Applicable fork diameter:

 

 

11Ø - 36Ø

 

 

 

 

 

 

 

Power supply/battery life:

Pre-installed batteries are for primarily for factory testing purpose. Their life may be shorter than replacement batteries.

 

 

 

 

Normal battery life as follows:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main unit:

 

 

CR2032 x 1 / approx. 2 years (When using 1 hour/day)

 

 

 

 

 

Heart rate sensor:

 

 

CR2032 x 1 / approx. 2 years (When attaching to body 1 hour/day)

 

 

 

 

 

Dimensions/Weight:

 

Main unit:

 

1-13/16" x 2-1/16" x 19/32" [46.0 x 52.5 x 14.4 mm] / 1.52 oz. [43 grams]

 

 

 

 

 

Heart rate sensor:

 

 

13" x 1-7/16" x 19/32" [330 x 36 x 15 mm] / 2.19 oz [62 grams]

 

Designs and specifications are subject to change without notice, due to modifications or improvements. *1) Windows 95/98 or Windows 2000 required; RS232C (serial port) needed

MSC-2Dx 30

Image 30
Contents Introduction Meaning of icons in this manual Quick chart Inside Carry BagAbout the Manuals Quick Start manualContents Correct USE of the CAT EYE MSC-2Dx Main Unit AccessoriesName of Various Sections and Parts Chest Belt Heart Rate SensorSUB Function Mode Button ModeButton Navigation Lap Button LAPStart/Stop Button S/S Reset OperationSet Button SET/AT All Clear Button ACFunctions MxS Maximum Speed Lap CountAvS Average Speed Dst Trip DistanceBefore Wearing Chest Belt Heart Rate Sensor Using the Heart Rate FunctionChest Belt Heart Rate Sensor Maximum transmitting distance about 90 cmWearing the Heart Rate Sensor Setting the Main Unit Setting Wheel CircumferenceChecking Wheel Circumference Setting Clock TimeSwitching Between Wheel Circumference a and B Changing Wheel CircumferencesPower Saving Feature FeaturesAuto Time Feature Auto Start/Stop Speed Pace FeatureLap Data Read Out Lap FeatureRecording Lap Data Downloading Lap DataSetting Heart Rate Target Zones Heart Rate Target ZoneTime In Heart Rate Zone Setting Alarm SoundResetting Time In Heart Rate Zone Downloading Time In Training ZoneProcedure for Memory Record Take the following steps to record data to memoryIcon must be off Memory Record Interval SelectionCheck the Memory Record Files Icon must be turned offSetting up Memory Record Stop and Mode buttons simultaneouslyCanceling Memory Record Memory Record On/OffTurning off icon before timing starts Memory Record Data Review Download Memory Record DataStop Elapsed Time TM must not be running Stop-state Memory Record How to downloadDownloading to a PC LapHeart Rate Training For improving your general fitnessFor competitors Trouble Shooting Clock setting screen does not appear Unit does not receive the heart rate signalYou cannot change the Interval Timer of memory record Heart rate display occasionally reads zeroMain Unit Replacing BatteryWireless Heart Rate Sensor CR2032Maintenance Replacing Electrode BeltDaily Care of the MSC-2Dx Specifications Registration Phone 303-443-4595 FAXAccessories Replacement partOptional part Index Heart rate target Lap