Precor EFX 885, EFX 835 warranty Repeat steps 2 through 4 to attach the right upright support

Page 19

Assembling the EFX

17

Important: Do not stretch, crimp, or damage the cable. Cables damaged by improper installation will not be covered by the Precor Limited Warranty.

Figure 3: Thread cable through upright support

3.Attach the left upright support to the base frame using four buttonhead screws, four split washers, and four ⁵₁₆-inch washers. Partially tighten the fasteners.

Figure 4: Attach the upright support to the base frame

4.Repeat steps 2 through 4 to attach the right upright support.

Image 19
Contents Assembling and Maintaining Elliptical Fitness Crosstrainers Page Page Trademark Note Edition InformationIntellectual Property Notice Safety Precautions Important Safety InstructionsPage Educating Users Product Recycling and Disposal Hazardous Materials and Proper DisposalRegulatory Notices for the Rfid Module Void the user’s authority to operate the equipment Radio Frequency Interference RFIFederal Communications Commission, Part Industry CanadaCardiovascular Type Equipment Safety Approvals for Cardiovascular EquipmentRegulatory Notices for Cardiovascular Exercise Equipment European ApplicationsUser’s authority to operate the equipment IEC-320 C13 and C14 plugs Obtaining Service Obtaining Updated DocumentationTable of Contents Commercial Cardiovascular Equipment Limited Warranty Assembling the EFX To prepare the EFX for assemblyHardware Kit not to scale Installation RequirementsFasteners Buttonhead screws Required Tools Performing the AssemblyTo begin assembly Is properly installedRepeat steps 2 through 4 to attach the right upright support EFX cable path Cable connection points inside EFX base To mount the center column support on the frame Lift cover replacementCenter column support attachment To tighten the fasteners properlyTighten the back fasteners on the upright supports To attach the upper body handlebars To attach the water bottle holderFully tighten the fasteners using a ⁹₁₆-inch box-end wrench Upright support cover attachment right-hand cover shown To attach the upright support covers and pivot arm capsAttach the pivot arm caps and seat them with a rubber mallet To level the unit Leveling the EFXBreaking in the Equipment Threading the Cable Assembly P80 Installing the ConsoleRemoving the access cover from the P80 console To thread the cable assemblyLocation Connecting Cables P80Cable Connector Type Circuit Location Connecting the Television CableTo connect the television cable Connecting the television cable Connecting the Ethernet and Base Unit Data CablesConnecting the Power Cable Connecting the Heart Rate Sensor CableThreading the Cable Assembly P30 Completing the Console Installation P80To complete the installation Console positioning on base unit Connecting Cables P30 Verifying That the Heart Rate Display Is Operational Completing the Console Installation P30To verify that the heart rate display is operational Daily Cleaning MaintenanceDaily Inspection Monthly Maintenance Weekly MaintenanceMoving the Equipment Storing the Chest StrapLong-Term Storage Minimum requirements for operation Self-Powered FeaturesRate of Motion Informational Displays Prior to Shutdown Symptoms of a Low BatteryOptional Power Adapter Kit Using the Optional Power AdapterReplacing the Battery Limited Warranty Commercial Cardiovascular Equipment Limited WarrantyWarranty Periods and Coverage Conditions and Restrictions Exclusive Remedies Complete this portion and keep for your records Exclusion of Consequential and Incidental DamagesCommercial Cardiovascular Equipment Limited Warranty Page Page Precor Incorporated Operating and Maintaining the P30 Console Page Page Edition Information Important Safety Instructions Operating and Maintaining the P30 Console  Do not lean on or pull on the console at any time Hazardous Materials and Proper Disposal Regulatory Notices for Cardiovascular Exercise Equipment 240 V Equipment Designated for U.S. Markets 240-volt, 20-amp power plug 120-volt, 20-amp power plugOperating and Maintaining the P30 Console 240 V Equipment Designated Operating and Maintaining the P30 Console Activating the Console for Self-Powered Equipment Activating the Console for Self-Powered EquipmentGetting Started Optional Use of the Power Adapter Identifying Parts of the Console Number Part Name Details Watts Number Part Name Details System Settings Setting Up the ConsoleNavigational keys for the system setting modes Key To view the Club Parameters settings5 1 5 6 Set Units All Equipment Setting Club Parameter ValuesSafety Code Treadmill only Select Language All EquipmentSet Max Pause Time All Equipment Set Max Workout Time All EquipmentSet Cool Down Time All Equipment Custom Program keys Equipment Key Name Description Creating a Custom WorkoutValue Range on or OFF To create a custom programSet Incline Limit Treadmill only Set Speed Limit Treadmill onlyHidden Programs Treadmill only Set Crossramp Auto Level EFX Dual only Set Resistance Range Bike onlyValue Range 0 to Value Information provided To view the System settingsViewing the Informational Displays Informational Displays valuesProduct Value Information provided Event LogEvent Description of Event Number User ID Entry with Csafe Equipment Csafe access keys Keys FunctionOperating and Maintaining the P30 Console Introducing Users to the P30 Console Using the Touch Heart Rate FeatureHeart rate target zones Heart rate strap Using a Chest Strap TransmitterTo use a chest strap transmitter Interfere with pacemakers or otherRestart switch Using the Treadmill Safety ClipAttaching the safety clip Treadmill Auto Stop Automatic Stop Function WORKOUT, Press QUICKSTART, or Enter to Begin Starting a WorkoutTo choose a workout goal before you begin exercising Starting a Preset Programmed WorkoutSetting Options To choose a language setting before you begin exercisingTo enter your Age and Weight during a workout Setting Options after You Begin a WorkoutTo choose a unit of measure before you begin exercising Paused Externally Powered Equipment Pausing and Resuming an Exercise SessionPending Shutdown Self-Powered Equipment Ending a Session Operating and Maintaining the P30 Console Interval ProgramsManual Heart RateVariety Weight LossPerformance To remove dust and dirt from the console Cleaning the Console and Display20031 142nd Avenue NE January Box Woodinville, WA USA