Precor EFX 835, EFX 885 warranty Event Description of Event Number

Page 86

28

 

Operating and Maintaining the P30 Console

 

 

 

 

Event

Description of Event

 

Number

 

 

 

 

 

09

Lower PCA memory test event

 

 

 

 

10

Line Frequency out of acceptable range

 

 

 

 

11

Watchdog (Upper PCA) low voltage power

 

 

 

 

12

Watchdog (Lower PCA) low voltage power

 

 

 

 

13

Fan at incorrect speed (version 1 treadmills)

 

 

 

 

14

Fan fail (lower PCA)

 

 

 

 

15

AC input voltage too high

 

 

 

 

16

AC input voltage too low

 

 

 

 

20

Too many maximum power requests in one second

 

 

 

 

21

Too many maximum consecutive power requests

 

 

 

 

22

No motor pulses at start up

 

 

 

 

23

Motor pulses missing after start up

 

 

 

 

24

Reduce speed requested, speed is not reducing

 

 

 

 

26

Motor pulse width incorrect

 

 

 

 

27

Too much drive motor current

 

 

 

 

28

Temperature too high

 

 

 

 

29

Excessive AC input current

 

 

 

 

30

Communications event lower board to upper board

 

 

 

 

31

Incorrect Communications event upper board to

 

 

lower board

 

 

 

 

32

Communication event upper board to lower board

 

 

 

 

33

Incorrect communications event lower board to

 

 

upper board

 

 

 

 

40

Lift motion detected

 

 

 

 

42

Lift position value out of range

 

 

 

 

43

Zero switch not found

 

 

 

 

44

Un-commanded lift motion

 

 

 

 

45

Lift going in the wrong direction

 

 

 

 

50

Too much brake (magnet) current

 

 

 

 

53

Cannot read target, cannot find home switch

 

 

 

 

54

Target pulses lost during operation

 

 

 

 

55

Brake home switch activated unexpectedly

 

 

 

 

60

Auto Stop sensor failure (treadmill)

 

 

 

 

61

Auto Stop not present (treadmill)

 

 

 

Image 86
Contents Assembling and Maintaining Elliptical Fitness Crosstrainers Page Page Intellectual Property Notice Edition InformationTrademark Note Important Safety Instructions Safety PrecautionsPage Educating Users Regulatory Notices for the Rfid Module Hazardous Materials and Proper DisposalProduct Recycling and Disposal Industry Canada Radio Frequency Interference RFIFederal Communications Commission, Part Void the user’s authority to operate the equipmentEuropean Applications Safety Approvals for Cardiovascular EquipmentRegulatory Notices for Cardiovascular Exercise Equipment Cardiovascular Type EquipmentUser’s authority to operate the equipment Obtaining Service Obtaining Updated Documentation IEC-320 C13 and C14 plugsTable of Contents Commercial Cardiovascular Equipment Limited Warranty To prepare the EFX for assembly Assembling the EFXFasteners Installation RequirementsHardware Kit not to scale Buttonhead screws Is properly installed Performing the AssemblyTo begin assembly Required ToolsRepeat steps 2 through 4 to attach the right upright support EFX cable path Cable connection points inside EFX base Lift cover replacement To mount the center column support on the frameTo tighten the fasteners properly Center column support attachmentTighten the back fasteners on the upright supports To attach the water bottle holder To attach the upper body handlebarsFully tighten the fasteners using a ⁹₁₆-inch box-end wrench To attach the upright support covers and pivot arm caps Upright support cover attachment right-hand cover shownAttach the pivot arm caps and seat them with a rubber mallet Leveling the EFX To level the unitBreaking in the Equipment Installing the Console Threading the Cable Assembly P80To thread the cable assembly Removing the access cover from the P80 consoleConnecting Cables P80 LocationTo connect the television cable Connecting the Television CableCable Connector Type Circuit Location Connecting the Ethernet and Base Unit Data Cables Connecting the television cableConnecting the Heart Rate Sensor Cable Connecting the Power CableTo complete the installation Completing the Console Installation P80Threading the Cable Assembly P30 Console positioning on base unit Connecting Cables P30 To verify that the heart rate display is operational Completing the Console Installation P30Verifying That the Heart Rate Display Is Operational Maintenance Daily CleaningDaily Inspection Weekly Maintenance Monthly MaintenanceLong-Term Storage Storing the Chest StrapMoving the Equipment Rate of Motion Self-Powered FeaturesMinimum requirements for operation Symptoms of a Low Battery Informational Displays Prior to ShutdownUsing the Optional Power Adapter Optional Power Adapter KitReplacing the Battery Warranty Periods and Coverage Commercial Cardiovascular Equipment Limited WarrantyLimited Warranty Conditions and Restrictions Exclusive Remedies Exclusion of Consequential and Incidental Damages Complete this portion and keep for your recordsCommercial Cardiovascular Equipment Limited Warranty Page Page Precor Incorporated Operating and Maintaining the P30 Console Page Page Edition Information Important Safety Instructions Operating and Maintaining the P30 Console  Do not lean on or pull on the console at any time Hazardous Materials and Proper Disposal Regulatory Notices for Cardiovascular Exercise Equipment 240 V Equipment Designated for U.S. Markets 120-volt, 20-amp power plug 240-volt, 20-amp power plugOperating and Maintaining the P30 Console 240 V Equipment Designated Operating and Maintaining the P30 Console Getting Started Activating the Console for Self-Powered EquipmentActivating the Console for Self-Powered Equipment Optional Use of the Power Adapter Identifying Parts of the Console Number Part Name Details Watts Number Part Name Details Setting Up the Console System Settings5 1 5 6 To view the Club Parameters settingsNavigational keys for the system setting modes Key Select Language All Equipment Setting Club Parameter ValuesSafety Code Treadmill only Set Units All EquipmentSet Cool Down Time All Equipment Set Max Workout Time All EquipmentSet Max Pause Time All Equipment To create a custom program Creating a Custom WorkoutValue Range on or OFF Custom Program keys Equipment Key Name DescriptionHidden Programs Treadmill only Set Speed Limit Treadmill onlySet Incline Limit Treadmill only Value Range 0 to Set Resistance Range Bike onlySet Crossramp Auto Level EFX Dual only Informational Displays values To view the System settingsViewing the Informational Displays Value Information providedEvent Log Product Value Information providedEvent Description of Event Number Csafe access keys Keys Function User ID Entry with Csafe EquipmentOperating and Maintaining the P30 Console Using the Touch Heart Rate Feature Introducing Users to the P30 ConsoleHeart rate target zones Interfere with pacemakers or other Using a Chest Strap TransmitterTo use a chest strap transmitter Heart rate strapUsing the Treadmill Safety Clip Restart switchAttaching the safety clip Treadmill Auto Stop Automatic Stop Function Starting a Workout WORKOUT, Press QUICKSTART, or Enter to BeginTo choose a language setting before you begin exercising Starting a Preset Programmed WorkoutSetting Options To choose a workout goal before you begin exercisingTo choose a unit of measure before you begin exercising Setting Options after You Begin a WorkoutTo enter your Age and Weight during a workout Pending Shutdown Self-Powered Equipment Pausing and Resuming an Exercise SessionPaused Externally Powered Equipment Ending a Session Operating and Maintaining the P30 Console Heart Rate ProgramsManual IntervalPerformance Weight LossVariety Cleaning the Console and Display To remove dust and dirt from the console20031 142nd Avenue NE January Box Woodinville, WA USA