Precor EFX 835, EFX 885 Set Max Workout Time All Equipment, Set Max Pause Time All Equipment

Page 80

22

Operating and Maintaining the P30 Console

Set Max Workout Time (All Equipment)

Value Range: 1 to 240 minutes

(Default: 60 minutes)

You can set a maximum workout time per session. Choose a time limit between 1 and 240 minutes, or select No Limit if you do not want to set a time limit. For example, if you set the time limit to 20 minutes, users can only enter a workout time between 1 and 20 minutes.

Select No Limit if you do not want to set a time limit.

Note: The Military Performance Programs will not complete if the maximum exercise time limit is less than 40 minutes. Set the maximum time about 40 minutes if you have enabled these performance programs.

Set Max Pause Time (All Equipment)

Value Range: 1 to 120 seconds

(Default: 120 seconds)

This setting limits how long equipment remains in a paused banner during a workout before it resets.

Note: The optional power adapter must be connected on self-powered equipment to establish a definitive pause time limit. If the optional power adapter is not attached and the rate of motion drops below the minimum requirements, the equipment begins its 30-second shutdown, effectively eliminating pause mode

Set Cool Down Time (All Equipment)

Value Range: 0 to 5 minutes

(Default: 5 minutes)

Select the maximum amount of time the equipment remains in the cool down mode. The cool down time is the period of time following the completion of a program when the user exercises at a reduced work rate.

Image 80
Contents Assembling and Maintaining Elliptical Fitness Crosstrainers Page Page Intellectual Property Notice Edition InformationTrademark Note Important Safety Instructions Safety PrecautionsPage Educating Users Regulatory Notices for the Rfid Module Hazardous Materials and Proper DisposalProduct Recycling and Disposal Radio Frequency Interference RFI Federal Communications Commission, PartIndustry Canada Void the user’s authority to operate the equipmentSafety Approvals for Cardiovascular Equipment Regulatory Notices for Cardiovascular Exercise EquipmentEuropean Applications Cardiovascular Type EquipmentUser’s authority to operate the equipment Obtaining Service Obtaining Updated Documentation IEC-320 C13 and C14 plugsTable of Contents Commercial Cardiovascular Equipment Limited Warranty To prepare the EFX for assembly Assembling the EFXFasteners Installation RequirementsHardware Kit not to scale Buttonhead screws Performing the Assembly To begin assemblyIs properly installed Required ToolsRepeat steps 2 through 4 to attach the right upright support EFX cable path Cable connection points inside EFX base Lift cover replacement To mount the center column support on the frameTo tighten the fasteners properly Center column support attachmentTighten the back fasteners on the upright supports To attach the water bottle holder To attach the upper body handlebarsFully tighten the fasteners using a ⁹₁₆-inch box-end wrench To attach the upright support covers and pivot arm caps Upright support cover attachment right-hand cover shownAttach the pivot arm caps and seat them with a rubber mallet Leveling the EFX To level the unitBreaking in the Equipment Installing the Console Threading the Cable Assembly P80To thread the cable assembly Removing the access cover from the P80 consoleConnecting Cables P80 LocationTo connect the television cable Connecting the Television CableCable Connector Type Circuit Location Connecting the Ethernet and Base Unit Data Cables Connecting the television cableConnecting the Heart Rate Sensor Cable Connecting the Power CableTo complete the installation Completing the Console Installation P80Threading the Cable Assembly P30 Console positioning on base unit Connecting Cables P30 To verify that the heart rate display is operational Completing the Console Installation P30Verifying That the Heart Rate Display Is Operational Maintenance Daily CleaningDaily Inspection Weekly Maintenance Monthly MaintenanceLong-Term Storage Storing the Chest StrapMoving the Equipment Rate of Motion Self-Powered FeaturesMinimum requirements for operation Symptoms of a Low Battery Informational Displays Prior to ShutdownUsing the Optional Power Adapter Optional Power Adapter KitReplacing the Battery Warranty Periods and Coverage Commercial Cardiovascular Equipment Limited WarrantyLimited Warranty Conditions and Restrictions Exclusive Remedies Exclusion of Consequential and Incidental Damages Complete this portion and keep for your recordsCommercial Cardiovascular Equipment Limited Warranty Page Page Precor Incorporated Operating and Maintaining the P30 Console Page Page Edition Information Important Safety Instructions Operating and Maintaining the P30 Console  Do not lean on or pull on the console at any time Hazardous Materials and Proper Disposal Regulatory Notices for Cardiovascular Exercise Equipment 240 V Equipment Designated for U.S. Markets 120-volt, 20-amp power plug 240-volt, 20-amp power plugOperating and Maintaining the P30 Console 240 V Equipment Designated Operating and Maintaining the P30 Console Getting Started Activating the Console for Self-Powered EquipmentActivating the Console for Self-Powered Equipment Optional Use of the Power Adapter Identifying Parts of the Console Number Part Name Details Watts Number Part Name Details Setting Up the Console System Settings5 1 5 6 To view the Club Parameters settingsNavigational keys for the system setting modes Key Setting Club Parameter Values Safety Code Treadmill onlySelect Language All Equipment Set Units All EquipmentSet Cool Down Time All Equipment Set Max Workout Time All EquipmentSet Max Pause Time All Equipment Creating a Custom Workout Value Range on or OFFTo create a custom program Custom Program keys Equipment Key Name DescriptionHidden Programs Treadmill only Set Speed Limit Treadmill onlySet Incline Limit Treadmill only Value Range 0 to Set Resistance Range Bike onlySet Crossramp Auto Level EFX Dual only To view the System settings Viewing the Informational DisplaysInformational Displays values Value Information providedEvent Log Product Value Information providedEvent Description of Event Number Csafe access keys Keys Function User ID Entry with Csafe EquipmentOperating and Maintaining the P30 Console Using the Touch Heart Rate Feature Introducing Users to the P30 ConsoleHeart rate target zones Using a Chest Strap Transmitter To use a chest strap transmitterInterfere with pacemakers or other Heart rate strapUsing the Treadmill Safety Clip Restart switchAttaching the safety clip Treadmill Auto Stop Automatic Stop Function Starting a Workout WORKOUT, Press QUICKSTART, or Enter to BeginStarting a Preset Programmed Workout Setting OptionsTo choose a language setting before you begin exercising To choose a workout goal before you begin exercisingTo choose a unit of measure before you begin exercising Setting Options after You Begin a WorkoutTo enter your Age and Weight during a workout Pending Shutdown Self-Powered Equipment Pausing and Resuming an Exercise SessionPaused Externally Powered Equipment Ending a Session Operating and Maintaining the P30 Console Programs ManualHeart Rate IntervalPerformance Weight LossVariety Cleaning the Console and Display To remove dust and dirt from the console20031 142nd Avenue NE January Box Woodinville, WA USA