Locate the Reed Switch (54) and the Magnet (42) on the left side of the Pulley (44). Turn the Pulley until the Magnet is aligned with the Reed Switch.

Make sure that the gap between the Magnet and the Reed Switch is about 1/8 in. (3 ram). If neces- sary, loosen the M4,2 x 19mm Screw (1), move the Reed Switch slightly, and then retighten the Screw,

Reattach the Motor Hood (not shown), and run the treadmill for a few minutes to check for a correct

speed reading.

PROBLEM: The incline of the treadmill does not change correctly

@

1/8 in.-

1j

54j

_44 = 42

Top

View

SOLUTION: a. With the key in the console, press one of the Incline buttons, While the incline is changing, re- move the key. After a few seconds, re-insert the key, The treadmill will automatically rise to the maximum incline level and then return to the minimum level. This will recalibrate the incline system.

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 11.

b.If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be- come damaged. Remove the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

2-3in. .-J_" , __

Idler Roller Bolts

c. If the walking belt still slows when walked on, see the back cover of this manual.

19

Image 19
Contents Maintenance Part List and Drawing AssemblySerial No Contents This product Products are used or where oxygen is being administeredDang ERA waysunplugthepower Before YOU Begin Assembly Page Page Page Page Codes InstalledIcone spray WillFeatures Oftheconsole ConsolediagramHOW to USE the Manual Mode HOW to Turn on the PowerMeasure your heart rate if desired Upper dis- play--TheHOW to USE a Preset Workout HOW to USE the Crosswalk Arms INFORMATiON ModeHOW to Move the Treadmill HOW to Fold the Treadmill for StorageHOW to Lower the Treadmill for USE Troubleshooting 44 = Page Workout Guidelines Health problemsOr any exercise program, consult your physi Exercise IntensityDescription Part LISTmModel No101 Hex Key Exploded Drawing AmModel No .24813.0 R0809A Exploded Drawing BmModel No .24813.0 ROSOgA Exploded Drawing CmModel No .24813.0 ROSOgA Exploded Drawing D--Model No .24813.0 RosogA MY-HOME IHHHi