Seiko 7K52 manual Accuracy of the alarm ± 1 minute

Page 32

English

 

 

Accuracy of the alarm: ± 1 minute

6

Battery

Miniature lithium battery SEIKO CR2016, 1 piece

 

 

Battery life: approx. 2 years

7

Battery life indicator

When the battery life nears its end, the small second hand

 

 

moves at 2-second intervals and the DEPTH hand points

 

 

to the 58-minute position before diving.

8

IC (Integrated Circuit)

C-MOS-LSI, 2 pieces

 

 

Semiconductor pressure sensor, 1 piece

9

Accuracy of sensors

 

 

Water depth

Within ± (Indicated value x 3.0% + 0.5 m) at a stable

 

 

temperature

 

 

[Influence of temperature change]

 

 

Within ± 1 m for a temperature change of 20° C

10

Magnetic resistance

4,800 A/m (60 gauss)

11

Water resistance

Withstands water pressure to a depth of 200 m and is

 

 

therefore suitable for scuba diving.

12

Safety design

The case, bracelet and buckle are rounded to prevent

 

 

damage to the diving suit or user’s skin.

* The specifications are subject to change without prior notice for product improvement.

32

Image 32
Contents Cal K52 English English English Contents TIME/CALENDAR SINGLE-TIME AlarmDiving Measurement Crown Screw lock type Small second handHOW to USE the Screw Lock Type Crown To unscrew the crown To screw in the crownTIME/CALENDAR Setting Adjusting the Hand Position Before Diving Press repeatedly until you hear a long beepHOW to Read the Measurements Diving MeasurementHOW to USE the Diving Function Press button B repeatedlyCase Rapid ascent warningRapid Ascent Warning Beep BeepExtra Measurement Range Warning Limit Abnormal Measurement / Measurement Halt WarningEnglish Recall of LOG Data Log data of the last diveLog data of the dive before last Diving hands at PositionRotating Bezel SINGLE-TIME Alarm Alarm Time SettingPrecautions for Diving Before DivingWhile Diving After Diving TIME/CALENDAR Setting Adjusting the Hand Position Before DivingExtra measurement range warning How to read the measurementsHow to use the diving function Remarks on the indication of MAX.DEPTH and Depth hands Recall of LOG DataAbnormal measurement / measurement halt warning SINGLE-TIME Alarm Battery Life Indicator Battery ChangeEnglish Necessary procedure after battery change HOW to USE the Diver Extender To extend the band lengthSpecifications Accuracy of the alarm ± 1 minute