ProSpot Fitness P-600 manual Trouble Shooting of ProSpot Systems

Page 20

Trouble-Shooting

How the Patented ProSpot System works:

Starting from the Computer Brain, a signal is sent from the left & right side, thru the L & R Grey Base Frame Wire Harness (white lead), to the Spiral Cord Harness (brown lead), to the Slider Block Cable Knuckle connector, to inside Barbell Cable to the Sensor on the Barbell. When skin contacts is made with Barbell Sensors, the signals return to the Computer Brain, at which a 12-volt charge is sent via the wire harness's (red & black leads), to the solenoids, to release the spring loaded Slider Block Locking Pins when the Barbell is lifted, allowing the Barbell to move up and down. When skin contact with Barbell Sensor is broken by either hand, the Computer Brain reads this and stops the 12-volt charge to the solenoids, at which time, the spring loaded Locking Pins instantaneously engages the hole on the Guide Post and locks the Barbell from any downward movement.

Trouble Shooting of ProSpot Systems

ALWAYS REMEMBER: After performing any service on the unit, RESET the Computer on your ProSpot system before using it. Just unplug the power supply Electronic Box, wait 30 seconds and plug back in. Resetting the Computer allows it to recalibrate and work to its greatest efficiency.

Electrical Service Inspection Checklist:

1.Check for proper functioning of wall receptacle. (Test plug for power)

a.If bad, find new AC power supply.

2.Check wall transformer connection to Electronic Box. Should not be bent or loose.

a.If bad, replace Electronic Box.

3.Check for green flashing light, the indication power to Electronic Box.

a.If no green light, test 12V Wall Adapter for 12-17 volts output.

4.Inspect white connectors from Gray Base Frame Wire Harness connection on Electronic Box for loose wires.

a.If loose, plug in tight.

b.If broken, replace Gray Base Frame Wire Harness.

5.Inspect Gray Base Frame Wire Harness for possible pinching in frame during assembly.

a.Replace Gray Base Frame Wire Harness if damaged or defective.

6.Inspect Gray Base Frame Wire Harness connection to Spiral Cord Harness.

a.If loose, plug in tight.

b.If broken, replace Gray Base Frame Wire Harness or Spiral Cord Harness.

7.Inspect Spiral Cord connection to Solenoids, Red and Black.

a.If loose, plug in tight.

b.If broken, replace Spiral Cord Harness.

8.Inspect Spiral Cord Brown Lead Sensor Cable Knuckle plug.

a.If loose, plug in tight.

b.If broken, replace Spiral Cord Harness.

9.Check contact of Sensor Collar Brass Pin with Cable Knuckle plate.

--20 --

Image 20
Contents PROSPOTfitness Model P-600 Instructions for Assembly of the ProSpotfitness P-600 Instructions for Assembly of the ProSpotfitness P-600 Step #2 Sensor Weight BAR Installation Step #6 Cable Installation Main Frame Assembly Main Frame Assembly Sensor Weight BAR Installation Electronic BOX Installation Cable Head Parts Diagram Spot Block Parts Diagram Weight Bar-Cable Knuckle Assembly & Trouble Shooting Diagram Read!! This Page Before Using Your ProSpotfitness Product User Instructions for the P-600 User Instructions for the P-600 Using Cable Crossover Sample Exercise List Maintenance Program ProSpotfitness PHL-600 Parts list Side Weight Stack Pulley Bracket Trouble Shooting of ProSpot Systems Trouble Shooting Warranty & Contact Information