Graco 222800 Series C important safety instructions Fire and Explosion Hazard

Page 5

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

DGround the equipment and the object being sprayed. Refer to Grounding on page 7.

DIf there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.

DProvide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.

DKeep the spray area free of debris, including solvent, rags, and gasoline.

DElectrically disconnect all equipment in the spray area.

DExtinguish all open flames or pilot lights in the spray area.

DDo not smoke in the spray area.

DDo not turn on or off any light switch in the spray area while operating or if fumes are present.

DDo not operate a gasoline engine in the spray area.

DKeep a fire extinguisher in the work area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

DKnow the specific hazards of the fluid you are using.

DStore hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

DAlways wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

308213 5

Image 5
Contents Important Safety Instructions Instructions-Parts ListPart No , Series C Standard MotorTable of Contents Equipment Misuse Hazard SymbolsSurgical treatment Skin Injection HazardFire and Explosion Hazard System Accessories Installation/OperationMounting Accessories Air Line AccessoriesObject being sprayed follow your local code GroundingFire and Explosion Hazard Before operating the pump, ground Preventive Maintenance Schedule Troubleshooting the Air MotorCheck Chart Air Motor CylinderUnder the cover 25, F 45 D Required Service Tools ServicePressure Relief Procedure Air Motor Shroud Air Valve Replacement106 Detail of Slide Plate SealsAir Motor Shroud Disassembly, on Air Valve Service107 104 104 103 102 1 101Moving Parts Hazard Air Motor Shroud Reassembly, on 308213 107 106 104 102 103 Follow the steps under Air Motor Shroud Disas- sembly on Subplate and Rocker Assemblies33z 24z 30z 32z 29z 31zPiston and Piston Rod Seals 11*z 14 2 11* z10z Model 222800 Premier Air Motor, Series C PartsDescription Qty See10z 32z 30z 31z 24z 33z 27zn 26zn Model 222800 Premier Air Motor, Series C shown Part No Air Valve, Series a 110 184485 SPRING, compression 111 184372 CARRIAGE, valve 109 184465112n 184484 SPRING, compression 113n 276064 GUIDE, plunger acetal 114n 184370Category Data Technical DataBottom View DimensionsGraco Information Graco Standard WarrantyToll Free Revision V, March