Weider WESY78732 user manual Upper Cable Adjustment

Page 12

UPPER CABLE ADJUSTMENT

After completing the assembly of the resistance system, the tension on the upper cable (A) will need to be adjusted. Also, the upper cable can stretch slightly when it is first used. When this occurs, the upper cable ten- sion will need to be readjusted. Follow the steps below to adjust the upper cable tension.

1.Connect the two Tension Gauges (118, 119) together using the magnet.

2.Plug in the resistance system as described in PLUGGING IN THE RESISTANCE SYSTEM on page 17. Use the Console (not shown) to adjust the resistance setting of the system to the highest setting, as described in Select a resistance setting on page 17.

Squeeze the upper cable (A) together near a Large Pulley (14). Hook the ends of the Tension Gauges (118, 119) around the upper cable as shown. Do not hook the ends of the Tension

Gauges around the Tether (70); which is attached to the back of the Pulley Bracket (10).

Slide the Tension Gauges (118, 119) next to the Large Pulley (14) as shown in the inset drawing.

3.Locate the 3/8” x 38mm Tension Screw (117) on each end of the Resistance Bar (9). Alternately tighten each Screw one turn at a time until the two Tension Gauges (118, 119) are pulled apart by the upper cable (A).

The upper cable tension is now properly adjusted.

1

 

 

 

 

 

118

 

 

 

 

 

Magnet

 

 

 

119

 

 

 

2

10

 

 

 

 

 

 

 

 

118

 

 

 

 

 

A

 

 

14

119

70

 

 

 

A

 

 

118

 

 

14

119

A

3

 

 

 

 

 

 

9

 

 

117

 

 

 

 

 

 

118

 

 

 

 

119

 

 

 

 

A

 

 

12

Image 12
Contents QUESTIONS? Model No. WESY78732 Serial NoCustomer HOT Line Table of Contents Keep hands and fingers clear of this area Important Precautions Before YOU Begin Assembly Make Things Easier for YourselfTighten the 1/2 x 25mm Screw Push the excess Upper Wire Harness 71 into the Upright Do not tighten the Locknut yet Sure that the upper cable a is between Two PulleysNot tighten the Bolt yet Page Rod Slot Upper Cable Adjustment Adjustments Remove the high pulleys when not in useUsing the LEG Lever Attaching the High PulleysAttaching the Accessories Attaching the Curl PADAttaching the Curl BAR Adjusting the Squat ARM Adjusting the BackrestAttaching the Squat Station Adjusting the Seat Storing the Resistance SystemFeatures of the Console Console OperationPlugging in the Resistance System Manual OperationProgram Operation Cable Diagram Upper Cable aTroubleshooting Cleaning the BAR GuidesAdjusting the Resistance Recalibrating the ConsoleExercise Guidelines Muscle Chart Cooling DownStaying Motivated Exercise Weight Sets Reps DateAerobic Exercise Thursday Aerobic Exercise DatePart Identification CHART-Model No. WESY78732 Part LIST-Model No. WESY78732 Key No. Qty DescriptionExploded DRAWING-Model No. WESY78732 R0204AOrdering Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT