Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Three
ABC
A. Loop system with standard elbows
B. Loop system with one offset and one standard elbow C. Vent system with one periscope (2" [51 mm] clearance)
NOTE: The following kits for close clearance alternate installations are available for purchase. Please reference the “Assistance or Service” section of the Washer/Dryer User Instructions.
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm) mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.
Determine vent length and elbows needed for best drying performance
Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and increased energy usage.
The Vent system chart provides venting requirements that will help to achieve the best drying performance.
Vent system chart
NOTE: Side exhaust installations add a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Number of | Type of Vent | Box or | Angled | ||
90º turns |
| Louvered | hoods | ||
or elbows |
| hoods |
|
| |
|
|
|
|
|
|
0 | Rigid metal | 43 | ft (13.1 m) | 36 | ft (11.0 m) |
|
|
|
|
|
|
1 | Rigid metal | 33 | ft (10.1 m) | 26 | ft (7.9 m) |
|
|
|
|
|
|
2 | Rigid metal | 23 | ft (7.0 m) | 16 | ft (4.9 m) |
|
|
|
|
|
|
14