Whirlpool W10222387A Alternate installations for close clearances, Vent system chart

Page 14

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Three close-clearance installations are shown. Refer to the manufacturer’s instructions provided with the vent system.

ABC

A. Loop system with standard elbows

B. Loop system with one offset and one standard elbow C. Vent system with one periscope (2" [51 mm] clearance)

NOTE: The following kits for close clearance alternate installations are available for purchase. Please reference the “Assistance or Service” section of the Washer/Dryer User Instructions.

Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch

Part Number 4396011 - 18" (457 mm) to 29" (737 mm) mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.

Determine vent length and elbows needed for best drying performance

Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

The Vent system chart provides venting requirements that will help to achieve the best drying performance.

Vent system chart

NOTE: Side exhaust installations add a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Number of

Type of Vent

Box or

Angled

90º turns

 

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

 

 

 

0

Rigid metal

43

ft (13.1 m)

36

ft (11.0 m)

 

 

 

 

 

 

1

Rigid metal

33

ft (10.1 m)

26

ft (7.9 m)

 

 

 

 

 

 

2

Rigid metal

23

ft (7.0 m)

16

ft (4.9 m)

 

 

 

 

 

 

14

Image 14
Contents 24 69 CM Electric WASHER/DRYER Installation Instructions LocationRequirements ToolsandPartsAlternateParts DrainSystem Installation ClearancesMobile Home Additional Installation Requirements Standpipe drain system wall or floor views a & BIt is your responsibility Electrical RequirementsFloor drain system view D Electrical ConnectionStyle 1 Power supply cord strain relief Electrical ConnectionStyle 2 Direct wire strain relief Wire connection Power supply cordWire connection Direct Wire E DCG F 25mm VentingRequirements Vent materialInstall the front leveling legs Install LevelingLegsInstall the rear leveling legs RemoveFoamPackingConnect Inlet Hoses SecureDrainHose PlanVentSystemVent system chart Alternate installations for close clearancesSpecial provisions for mobile home installations Determine vent pathLevelWasher/Dryer Install VentSystemCompleteInstallation ConnectVentW10222387A