3.Move the green painted screw from the internal to the external ground location. Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw.
B
A C
G F E D
A. Neutral wire (white or center wire)
B. Center
C. Neutral ground wire
D. External ground conductor screw
E. Ground wire (green or bare) of power supply cable
F. Internal ground conductor location
G. ¾" (19 mm) UL listed strain relief
4.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
5.Tighten strain relief screw.
6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
7.You have completed your electrical connection. Now go to “Venting Requirements.”
Use where local codes permit connecting
B D E
A
CG F
A.
B.
C.Neutral prong
D.Spade terminals with upturned ends
E.3⁄4" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
1.Loosen or remove center
2.Connect neutral wire (white or center wire) of power supply cord to the center
B
A
C
E D
A. Neutral wire (white or center wire)
B. Center
C. Neutral ground wire
D. Internal ground conductor screw
E. ¾" (19 mm) UL listed strain relief
3.Connect the other wires to outer terminal block screws. Tighten screws.
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
6.You have completed your electrical connection. Now go to “Venting Requirements.”
8