Electrical Connection

Power Supply Cord

 

Direct Wire

 

 

 

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire. Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

1.Disconnect power.

2.Remove the hold-down screw and terminal block cover.

A

B

D C

3.Install strain relief.

Style 1: Power supply cord strain relief

Remove the screws from a 34" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.

A

B

C

D

A. Strain relief tab pointing up

B. Hole below terminal block opening

C. Clamp section

D. Strain relief tab pointing down

A. Center silver-colored terminal block screw B. Hold-down screw

C. Terminal block cover

D. Internal ground conductor screw

5

Image 5
Contents 24 69 CM Electric WASHER/DRYER Installation Instructions LocationRequirements ToolsandPartsAlternateParts Mobile Home Additional Installation Requirements Installation ClearancesDrainSystem Standpipe drain system wall or floor views a & BFloor drain system view D Electrical RequirementsIt is your responsibility Electrical ConnectionElectrical Connection Style 1 Power supply cord strain reliefWire connection Power supply cord Style 2 Direct wire strain reliefE D Wire connection Direct WireCG F 25mm Vent material VentingRequirementsInstall the rear leveling legs Install LevelingLegsInstall the front leveling legs RemoveFoamPackingConnect Inlet Hoses PlanVentSystem SecureDrainHoseSpecial provisions for mobile home installations Alternate installations for close clearancesVent system chart Determine vent pathCompleteInstallation Install VentSystemLevelWasher/Dryer ConnectVentW10222387A