7. TROUBLESHOOTING
7-1. BEFORE PERFORMING SERVICE
Be careful of electric shock or disconnecting the parts while troubleshooting.
Voltage of each terminal in
7-2. QC TEST MODE.
Pressing Temp, and Option button simultaneously. |
|
|
Power supply ON with pressing upper two button. |
| Option |
Press the START/PAUSE button as follows. | Temp. | |
Press the START/PAUSE button more 4 times until stop spinning |
| |
|
|
Pressing number of | Checking Point | |
START/PAUSE button |
| |
None | All lamps turn on | |
|
| |
1 time | Clockwise spin (right) | |
|
| |
2 times | Low speed spin | |
|
| |
3 times | High speed spin | |
|
| |
4 times | Inlet valve for | |
|
| |
5 times | Inlet valve for | |
| ||
Hot inlet valve in case of hot water fill | ||
| ||
|
| |
6 times | Inlet valve for | |
|
| |
7 times | Counterclockwise spin (left) | |
|
| |
8 times | A Heater is in operation for 3 sec. | |
|
| |
9 times | Draining pump operation | |
|
| |
10 times | Auto off operation | |
|
|