Whirlpool 8TCEM2760KQ0 Tools and Parts, Location Requirements, Tools needed, Parts supplied

Page 4

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

8" or 10" Pipe wrench

8" or 10" adjustable wrench

Flat-blade screwdriver

Phillips screwdriver

Adjustable wrench that opens to 1" (2.5 cm) or hex-head socket wrench

Level

⁵⁄₁₆" socket wrench

Utility knife

Vent clamps

Pipe-joint compound resistant to LP gas

Caulk gun and caulk (for installing new exhaust vent)

Pliers

Putty knife

Parts supplied

Remove parts bag from dryer drum. Check that all parts were included.

Wedge cone

Foot boot (4)

Dryer foot (4)

⁵⁄₁₆"-18 x 2 ¹⁄₂" bolt

3 pin timing cam

6 pin timing cam

Location Requirements

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Do not install in a garage.

Failure to do so can result in death, explosion, or fire.

If installing a gas dryer:

IMPORTANT: Observe all governing codes and ordinances.

Check code requirements: Some codes limit or do not permit installation of clothes dryers in garages, closets, or sleeping quarters. Contact your local building inspector.

Make sure that lower edges of the cabinet, plus the back and bottom sides of the dryer, are free of obstructions to permit adequate clearance of air openings for combustion air. See “Recessed Area and Closet Installation Instructions” below for minimum spacing requirements.

NOTE: The dryer must not be installed in an area where it will be exposed to water and/or weather.

Recessed Area and Closet Installation Instructions

This dryer may be installed in a recessed area or closet. For recessed area and closet installations, minimum clearances can be found on the serial tag on the dryer.

The installation spacing is in inches and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.

The dryer must be exhausted outdoors.

No other fuel-burning appliance may be installed in the same closet as the dryer.

4

Image 4
Contents Installation Instructions Dryer Safety What to do if YOU Smell GAS Recessed Area and Closet Installation Instructions Tools and PartsLocation Requirements Tools neededProduct Dimensions 27 68.6 cm dryer Product Dimensions 29 73.7 cm dryerElectrical Requirements Electric Dryer Electrical Requirements Gas DryerRecommended Ground Method Gas Supply Requirements Type of GasVenting Requirements Gas Supply Pressure TestingGas Supply Line Vent System Length Multiple Dryer Venting Maximum Vent LengthComplete Installation Install Coin Slide and Coin BoxConnect Vent Power Supply Cord Method U.S. Only Make Electrical ConnectionPower Supply Cord, Four-wire electrical connection Power Supply Cord, Three-wire electrical connection EDCDirect Wire Method U.S. Only Direct Wire Four-wire electrical connectionDirect Wire Three-wire electrical connection Loosen or remove the center terminal block screwChanging to a 30- or 60-MINUTE Timing CAM Maintenance instructions 2006 05/2006 W10103110 Page Page Page 35.6 cm 38.1 cm 27 68.6 cm 5 cm Page Page Page No. of 90 turns Page Page Page EDC ¹⁄₂ 8.9 cm 12.7 cm 2 8.9 cm Page Page W10103110