Page 6

Electrical Requirements – Gas Dryer

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

A 120-volt, 60-Hz, AC-only, 15- or 20-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this dryer be provided.

Recommended Ground Method

The dryer, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition, and all local codes and ordinances.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Electrical Requirements – Electric Dryer

IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.

The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

A four-wire or three-wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply (or four-wire or three-wire, 120/208-volt, if specified on the model/serial rating plate) is required on a separate, 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.

6

Image 6
Contents Installation Instructions Dryer Safety What to do if YOU Smell GAS Location Requirements Recessed Area and Closet Installation InstructionsTools and Parts Tools neededProduct Dimensions 27 68.6 cm dryer Product Dimensions 29 73.7 cm dryerElectrical Requirements Gas Dryer Electrical Requirements Electric DryerRecommended Ground Method Gas Supply Requirements Type of GasGas Supply Pressure Testing Venting RequirementsGas Supply Line Vent System Length Multiple Dryer Venting Maximum Vent LengthInstall Coin Slide and Coin Box Complete InstallationConnect Vent Power Supply Cord Method U.S. Only Make Electrical ConnectionPower Supply Cord, Four-wire electrical connection Power Supply Cord, Three-wire electrical connection EDCDirect Wire Method U.S. Only Direct Wire Four-wire electrical connectionDirect Wire Three-wire electrical connection Loosen or remove the center terminal block screwChanging to a 30- or 60-MINUTE Timing CAM Maintenance instructions 2006 05/2006 W10103110 Page Page Page 35.6 cm 38.1 cm 27 68.6 cm 5 cm Page Page Page No. of 90 turns Page Page Page EDC ¹⁄₂ 8.9 cm 12.7 cm 2 8.9 cm Page Page W10103110