Whirlpool L-63 manual Exhaust Requirements for Gas and Electric Dryers Fire Hazard

Page 10

Exhaust Requirements for Gas and Electric Dryers

!WARNING

Fire Hazard

Do Not use nonmetal, flexible duct. Do Not use metal duct smaller that four inches in diameter. Do Not use exhaust hoods with magnetic latches. Improper air supply for exhausting may result in a fire. Check that exhaust system is not longer than specified. Exhaust systems longer than specified will:

Accumulate lint

Shorten the life of the product

Reduce performance and result in longer drying times and increased energy usage. Failure to follow these specifications may result in a fire.

Do Not exhaust dryer into a chimney, furnace cold air duct, attic or crawl space, or any other duct used for venting. Clean the exhaust system every other year. Do Not install flexible duct under wall, ceiling or floor materials. Accumulated lint could result in a fire or cause moisture damage.

Four inch Rigid Metal Duct is preferred. Four-inch flexible metal duct may be used.

Metal flexible duct must be fully extended and supported when the dryer is in its final position. DO NOT KINK OR CRUSH THE DUCT. The metal flexible duct must be completely open to allow adequate exhaust air to flow.

Plan installation to use the fewest number of elbows and turns. Allow as much room as possible when using elbows or making turns. Bend duct gradually to avoid kinking. Remove excess flexible duct to avoid sagging and kinking that may result in reduced air flow.

Use duct tape to seal all joints.

The Exhaust duct can be routed down, left, right, or straight out the back of the dryer. Space requirements are provided in the Installation Instructions.

Minimum length of rear exhaust system depends upon the type of duct used, number of elbows and the type of exhaust hood. The maximum length for both rigid and flexible ducts is shown in chart.

Side or bottom exhaust maximum length is 16 feet with two external elbows.

Exhausting the dryer outside is preferred.

Four inch Rigid Metal Duct is preferred. Four-inch flexible metal duct may be used.

Metal flexible duct must be fully extended and supported when the dryer is in its final position. DO NOT KINK OR CRUSH THE DUCT. The metal flexible duct must be completely open to allow adequate exhaust air to flow.

5

Image 10
Contents Electric & GAS Dryers Introduction Table of Contents Section Four Page Electrical Shock Hazard Electrical RequirementsElectrical Requirements for Gas Dryers Recommended Grounding MethodElectrical Requirements for Electric Dryers Electrical ConnectionGrounding Instructions Page Exhaust Requirements for Gas and Electric Dryers Fire Hazard Gas Requirements for Gas Dryers Page Recessed and Closet Installation Instructions Potential Fire HazardElectronic Dry-Miser Console Timer ControlSection TWO Timed Dry CycleVersion Electronic Dryer Control Clean Touch Control PADPUSH-TO-START Knob Fluff Air CycleHeated Air Circulation Side and Bottom Exhaust Venting Kit Console Control Repairs Section ThreeRemoving the Console Removing the Push to Start Switch Removing the TimerRemoving the Clean Touch Switch Assembly Removing the BuzzerReplacing the Drum Lamp Removing the Door SwitchRemoving the Toe Panel Removing Blower Housing Replacing the Blower WheelReplacing the Operating Thermostat and Bias Heater Replacing the MotorReplacing the Thermal Fuse Replacing the Heating Element Electric Dryers Removing the Burner Assembly Gas DryersReplacing the Heat Duct Assembly Replacing the High Limit Thermostat and Thermal CutoffRemoving the Dryer Door Removing the Front PanelRemoving the Belt and the Drum Replacing the Grille AssemblyReplacing the Front Support Rollers and Shafts Removing the Rear Bulkhead Assembly Reattaching the Rear BulkheadPage Troubleshooting Guide Section FourTimer Shuts Off but Clothes are Still Damp Component TestingTimer Does Not Advance but Clothes are Dry Section Five Wiring DiagramElectric Dryer Gas Dryer Timer Schedule Strip CircuitsPage Page MODEL/SERIAL Number Designations MODEL/SERIAL Number Plate Location100003 Rprt