Whirlpool 3395339 manual Recessed area and closet Installations, Closet View, Product dimensions

Page 7

Recessed area and closet Installations

Fire/Health Hazard

Exhaust dryers to the outside to prevent exposure to substances in the gas fuels and combustion byproducts which may be harmful to your health.

Failire to do so may result in a fire or health hazard.

L

This appliance may be installed in a recessed area.

The installation spacing is the minimum allowable. Additional spacing should be considered for ease of installation, servicing and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air openings in the top and bottom are required. Door must have two centered openings as illustrated. Both openings must provide a minimum of 72 square inches of unobstructed airflow as shown. Louvered doors with equivalent air openings are acceptable.

FOR CLOSET INSTALLATIONS, TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE FROM ACCUMULATING, TO MAINTAIN DRYING EFFICIENCY, AND TO PREVENT EXPOSURE TO POSSIBLE HEALTH HAZARDS, DRYERS MUST BE EXHAUSTED OUTDOORS.

+

4

0”

Additional clearances may be required for wall. door and floor moldings if external exhaust elbow is used.

Recessed front view

 

 

Closet

view

 

 

Side

view

 

 

 

 

 

 

Additional

 

Additional

clearances

for

space

may

wall,

door

and

be

needed

floor

moldings

for

exhaust

may

be

 

elbow.

 

required.

 

I- 7”

Opening is minimum for closet door. Louvered door with equivalent air openings is acceptable.

Front view

Companion appliance spacing should be considered.

No other fuel-burning appliance may be installed in the same closet.

Product dimensions

Side view

r

approx.

Rear view

pJ

llB/ kttom exhaust

To change to a 30- or 60-minute timing cam

Electrical Shock Hazard

Disconnect both power supply cords from the electric power supply before making these changes. Change timing cams before completing electrical connection.

Failure to follow these instructions may result in electrical shock or personal injury.

Each dryer is equipped with a 45 minute timer cam that provides 45 minutes of drying time when activated by the coin slide.

You can install the 30-minute or 60- minute timing cam (shipped with each dryer) as follows:

1.Unlock control panel. Lift up and rotate out from cabinet. Control panel WIII STIIIDe attached to cabinet.

2.Reach into control panel area. Use a Phillips screwdriver to loosen (but not remove) timer mounting bracket screw. Lift up to remove timer assembly and bracket from cabinet.

ratchet tooth

3.Turn the timing cam by hand until the ‘I/“-shaped notch lines up below the ratchet tooth.

Page 7

Image 7
Contents Lnst btiol Important Observe all governing codes and ordinances Before you startWhat to do if YOU Smell GAS Gas supply reauirements Tools needed for installationParts supplied For Parts owner must supplyKz+rdmended grounding Electrical requirementsExhaust materials are not supplied Exhaust requirementsExhaust Hood Type To connect exhaust duct straight out the back Exhaust duct connectionProduct dimensions Recessed area and closet InstallationsCloset View With dryers in laundry area Now startMove unit to its permanent location 14 w16.7.9 Move dryers to a New location If dryers do not Operate properlyIf you need Assistance