Tools needed for installation:
adjustable | wrench | level | |
utility | knife |
| pliers |
Phillips | screwdriver | duct tape |
Parts supplied | for | |||
hstallation: |
|
| ||
2 | slide | protectors | 8 screws |
|
2 | slide | extensions | cams | |
2 | bolt | and washer | cams | |
assemblies | 4,3/4” wood | screws |
Parts owner must supply:
1 control panel lock and key
2 coin vaults and keys (E.S.D. vault must have projecting lock.)
2
Parts may be ordered from Greenwald Industries, Inc. or Equipment Systems and Devices, Inc.
l Greenwald Industries, Inc.
1340 Metropolitan Avenue Brooklyn, NY 11237 telephone (7 18) 82
fax no. (718)
l Equipment Systems and Devices, Inc.
270 New Jersey Dr.
Fort Washington, PA 19034 telephone (2 15)
fax no. (2 15)
Gas supply reauirements
a
Fire Hazard
l These dryers must be connected to a regulated gas supply.
Failure to do so could result in high- pressure gas release, resulting in a fire or explosion.
l Have L.P. gas checked by a qualified person before installing the dryer. The L.P. gas supply must not exceed a pressure of 13” water column.
l New flexible tubing should be used. Reusing old, flexible tubing might result in possible leaks or fire hazard.
Failure to follow these instructions could result in fire or explosion.
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
A n This installation must conform with American National Standard, National Fuel Gas Code ANSI 2223. l- latest edition”, and all local codes and ordinances.
B n The desian of this drver has been certified bv the American Gas Association for use at altitudes up to 10,000 feet above sea level at the B.T.U. rating indicated on the model/serial plate. Burner input adjustments are not required when the dryer is operated up to this elevation.
When installed above 10,000 feet, a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial plate is required for each 1,000 foot increase in elevation. For assistance when converting to other gas types and/or installing above 10,000 feet elevation, contact your local service company.
C n Check that dryers are equipped with the correct burner for the particular type of gas used. Burner information will be found on the rating plate in door well of the appliance. If this information does not agree with the type of gas available, see your dealer.
D n These dryers are shipped for use with NATURAL GAS. They are certified by the American Gas
Association for manufactured, mixed and L.P. (propane and butane) gases
with appropriate conversion. No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician. Gas conversion kit part numbers are listed on the gas valve burner base.
E n Provide a rigid gas supply line of
FH If local codes and ordinances
permit, it is recommended that new flexible metal tubing,
G n The supply line shall be equipped with a shutoff valve. This valve should be located in the same room as the dryers and should be in a location that allows ease of opening and closing. Do Not block access to shutoff valve.
main gas supply line, a combination of fittings must be used to obtain an
I n Make sure lower edges, back and sides of the cabinet are free of obstructions to permit adequate clearance of air openings for combustion air. See “Recessed area and closet installation instructions” for minimum spacing requirements.
J n For ease of installation, operating and servicing (if ever needed), adequate space should be provided around the dryers.
K n A
The dryers and their individual shutoff
valves must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of l/2 psig (3.4 kPa).
The dryers must be isolated from the gas supply piping system by closing their individual manual shutoff valves during any pressure testing of the gas supply piping system at test pressures equal to or less than l/2 psig
(3.4 kPa).