ToolsandParts

Tools needed

Gather the required tools and parts before starting installation. Read and follow the safety instructions provided with any tools listed here.

A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the dryer weight (dryer and load) of 115 lbs (52 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1" (2.5 cm) under entire dryer.

Flat-blade screwdriver

Level

Adjustable wrench

T20 Torx screwdriver

Wire stripper (direct wire installations)

Wood block

7 mm nutdriver

Caulking gun and compound (for installing new exhaust vent)

Tin snips (new vent installations)

Vent clamps

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Parts supplied

Remove parts package from the dryer drum. Check that all parts listed are included.

Coupling

Parts needed

Check local codes, existing electrical supply and venting, and see “Venting Requirements” and “Electrical Requirements” before purchasing parts.

LocationRequirements

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need

A location that allows for proper exhaust installation. See “Venting Requirements.”

A separate 30-amp circuit.

Installation Clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

39"

(99.1cm)*23¹⁄₄"

(60.3cm)

33¼"

(84.45cm)

23³⁄₈"

(59.37cm)

*Most installations require a minimum 5½" (14.0 cm) clearance behind the dryer for the exhaust vent with elbows. See “Venting Requirements.”

Minimum installation spacing for recessed area and closet installation

The following dimensions shown are for the minimum spacing allowed when the dryer is to be operated with, or without, the Stack Kit. To purchase a Stack Kit, see “Assistance or Service.”

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

4

Image 4
Contents Electric Dryer 8565592ATable of Contents Dryer Safety Your safety and the safety of others are very importantToolsandParts Installation InstructionsLocationRequirements Recessed or closet installation Dryer only Electrical RequirementsIt is your responsibility Mobile Home Additional Location RequirementsIf connecting by direct wire If using a power supply cordIf your outlet looks like this Direct Wire Power Supply CordElectrical Connection Wire connection Power supply cord DEFWire connection Direct Wire CE FVentingRequirements Alternate installation for close clearances Special provisions for mobile home installationsPlan VentSystem Determine vent lengthInstall VentSystem CompleteInstallationLevelDryer ConnectVentDryer USE Starting YourDryerStoppingandRestarting To stop your dryer at any timeDrying,Cycle,andTemperatureTips ChangingCyclesandTemperaturesCycles TemperatureControl CleaningtheDryer LocationCleaningtheLintScreen Dryer CareCleaningtheDryerInterior CleaningtheControlPanelRemovingAccumulatedLint VacationandMovingCareTroubleshooting Assistance or Service TheU.S.APage Whirlpool Corporation will not pay for 8565592A