4-wire connection: Direct Wire

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.

Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5" (12.7 cm). Cut 1¹⁄₂" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.

5.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

6.Replace the terminal block cover on the back of the dryer.

7.Tighten strain relief nut.

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw. See example below.

1.Locate the neutral grounding wire (green with yellow stripes) inside the dryer cabinet, behind the external ground conductor screw. Remove this wire.

A

A. Remove neutral grounding wire (green with yellow stripes)

2.Loosen or remove center terminal block screw.

3.Connect ground wire (green or bare) of power supply cord to external ground conductor screw. (If power supply cord has ring terminals, the ground conductor screw will need to be removed to make the connection.) Tighten screw.

4.Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

C

B

D

A

A. Neutral wire (white or center wire)

B. Center terminal block screw

C. External ground conductor screw

D. Green or bare wire of power supply cable

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

BD

A

CE F

A. 3-wire receptacle (NEMA type 10-30R)

B. 3-wire plug

C. Neutral prong

D. Spade terminals with upturned ends

E. Neutral (white or center wire)

F. Ring terminals

1.Loosen or remove center terminal block screw.

2.Connect neutral wire (white or center wire) of power supply cord under center screw of the terminal block. Tighten screw.

B

A

A. Neutral wire (white or center wire)

B. Center terminal block screw

3.Connect the other wires to outer terminal block screws. Tighten screws.

4.Replace the terminal block cover on the back of the dryer.

5.Tighten strain relief nut.

9

Image 9
Contents 8565592A Electric DryerTable of Contents Your safety and the safety of others are very important Dryer SafetyInstallation Instructions ToolsandPartsLocationRequirements Electrical Requirements Recessed or closet installation Dryer onlyIt is your responsibility Mobile Home Additional Location Requirements If using a power supply cord If connecting by direct wire If your outlet looks like this Power Supply Cord Direct WireElectrical Connection DEF Wire connection Power supply cordCE F Wire connection Direct WireVentingRequirements Special provisions for mobile home installations Alternate installation for close clearancesPlan VentSystem Determine vent lengthCompleteInstallation Install VentSystemLevelDryer ConnectVentStarting YourDryer Dryer USEStoppingandRestarting To stop your dryer at any timeChangingCyclesandTemperatures Drying,Cycle,andTemperatureTipsCycles CleaningtheDryer Location TemperatureControlCleaningtheLintScreen Dryer CareCleaningtheControlPanel CleaningtheDryerInteriorRemovingAccumulatedLint VacationandMovingCareTroubleshooting TheU.S.A Assistance or ServicePage 8565592A Whirlpool Corporation will not pay for