IMPORTANT SAFETY INSTRUCTIONS

￿WARNING - Risk of Fire

￿To reduce the risk of severe injury or

death, follow all installation instructions.

￿Clothes dryer installation must be performed by a qualified installer.

￿Install the clothes dryer according to the manufacturer's instructions and local codes.

￿Repair and maintenance work should be performed by a Miele authorized service technician. Work by unqualified persons could be dangerous and could void the warranty.

￿Before installation, disconnect the tumble dryer from the electrical supply by shutting off the power main, unplugging the power cord or tripping the circuit breaker. Do not restore power until the installation is complete.

￿GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

￿WARNING – Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the appliance is properly grounded.

￿Do not modify the plug provided with the appliance! If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

￿Do not use an extension cord to connect this appliance to the power supply. Extension cords do not guarantee the required safety of the appliance (e.g. danger of overheating).

￿This dryer must be vented outdoors to reduce the risk of fire. Be sure to observe local building codes.

￿Do not install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.

￿Use flexible or rigid metal pipe for venting. Non-metallic flexible hose should not be used, it is a potential fire hazard.

￿The appliance shall not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl space, or a concealed space of a building.

22

Image 26
Contents Vented Dryer 8002 T 8003 T Contents Important Safety Instructions This dryer is intended for residential use only Grounding InstructionsControl panel Before loading the dryer Program recommendationsSelect a program Using the dryerTurn on the dryer and load the laundry Program When to use Extra DryFull load Select a drying option if neededTurbo GentleSelect the buzzer if desired To adjust the buzzer volumeSelect the dryness level Start the program At the end of a programCanceling or changing a program Adding or removing laundry during a programTo activate the child lock Child lockChild lock To deactivate the child lockCleaning the lint filters Dryer careCleaning the grille filters Cleaning the exterior and the control panel Cleaning the drumChanging the light bulb What if the Filter/Vent fault indicator is lit? Frequently asked questionsWhat if the dryer will not run? Possible fault Solution Possible fault SolutionWhat if the laundry is not dry enough? Possible fault Repairs After sales servicePC Update MieleCareQuick Guide Remove this guide for easy referenceSelect a program Quick GuideTurn on the dryer and load the laundry Select a drying option if desiredQuick Guide At the end of a programFor uniform loads, e.g. sheets Underwear, socks Installation Instructions Important Safety Instructions Save These Instructions Height of vent adapter in a stacked installation Washer / Dryer StackElectrical connection Installation Transporting the dryer to the installation site InstallationInstallation site Rear viewInstallation beneath a counter Reinstallation of the machine lidChanging the position of the exhaust connection Leveling the dryerDetermining the position of the exhaust connection Installation tips Room ventilationWall connection with rigid pipe Exhaust connectionWindow connection Direct wall connection Dryer top viewHow to calculate the effective duct length Tips about the duct work Additional duct lengths 4 rigid pipe only Length Disposal of an appliance Caring for the environmentDisposal of the packing materials Page