Page 35

Installation

Exhaust connection

Using the connector supplied, an exhaust hose (4" [100 mm] diameter) can be installed.

Necessary materials:

a wall or window duct (available from Miele)

an exhaust hose/pipe made of approved non-flammable material

￿Install the exhaust hose/pipe, 2, with the connector, 1, to the dryer.

Window connection

1Window duct ( (installed in a "plexiglass" pane)

2Connector for the flexible metal exhaust hose

Wall connection with rigid pipe

1Wall pipe (Installation sheet supplied with the Miele wall pipe)

2Connector

3Rigid pipe

31

Image 35
Contents Vented Dryer 8002 T 8003 T Contents Important Safety Instructions Grounding Instructions This dryer is intended for residential use onlyControl panel Program recommendations Before loading the dryerSelect a program Using the dryerTurn on the dryer and load the laundry Extra Dry Program When to useGentle Select a drying option if neededTurbo Full loadSelect the buzzer if desired To adjust the buzzer volumeSelect the dryness level At the end of a program Start the programAdding or removing laundry during a program Canceling or changing a programTo deactivate the child lock Child lockChild lock To activate the child lockDryer care Cleaning the lint filtersCleaning the grille filters Cleaning the drum Cleaning the exterior and the control panelChanging the light bulb Possible fault Solution Frequently asked questionsWhat if the dryer will not run? Possible fault Solution What if the Filter/Vent fault indicator is lit?What if the laundry is not dry enough? Possible fault MieleCare After sales servicePC Update RepairsRemove this guide for easy reference Quick GuideSelect a drying option if desired Quick GuideTurn on the dryer and load the laundry Select a programAt the end of a program Quick GuideFor uniform loads, e.g. sheets Underwear, socks Installation Instructions Important Safety Instructions Save These Instructions Washer / Dryer Stack Height of vent adapter in a stacked installationElectrical connection Installation Rear view InstallationInstallation site Transporting the dryer to the installation siteReinstallation of the machine lid Installation beneath a counterChanging the position of the exhaust connection Leveling the dryerDetermining the position of the exhaust connection Room ventilation Installation tipsWall connection with rigid pipe Exhaust connectionWindow connection Dryer top view Direct wall connectionHow to calculate the effective duct length Tips about the duct work Additional duct lengths 4 rigid pipe only Length Disposal of an appliance Caring for the environmentDisposal of the packing materials Page